TY - JOUR
T1 - A developed determination of midazolam and 1′-hydroxymidazolam in plasma by liquid chromatography-mass spectrometry
T2 - Application of human pharmacokinetic study for measurement of CYP3A activity
AU - Shimizu, Mikiko
AU - Uno, Tsukasa
AU - Tamura, Hiro omi
AU - Kanazawa, Hideko
AU - Murakami, Isao
AU - Sugawara, Kazunobu
AU - Tateishi, Tomonori
PY - 2007/3/1
Y1 - 2007/3/1
N2 - This paper describes sensitive and reliable determination of midazolam (MDZ) and its major metabolite 1′-hydroxymidazolam (1-OHMDZ) in human plasma by liquid chromatography-mass spectrometry (LC-MS) with a sonic spray ionization (SSI) interface. MDZ, 1-OHMDZ and diazepam as an internal standard were extracted from 1 ml of alkalinized plasma using n-hexane-chloroform (70:30, v/v). The extract was injected into an analytical column (YMC-Pak Pro C18, 50 mm × 2.0 mm i.d.). The mobile phase for separation consisted of 10 mM ammonium acetate and methanol (50:50, v/v) and was delivered at a flow-rate of 0.2 ml/min. The drift voltage was 100 V. The sampling aperture was heated at 120 °C and the shield temperature was 260 °C. The total time for chromatographic separation was less than 16 min. The validated concentration ranges of this method were 0.25-50 ng/ml for both MDZ and 1-OHMDZ. Mean recoveries were 93.6% for MDZ and 86.6% for 1-OHMDZ. Intra- and inter-day coefficient variations were less than 6.5 and 5.5% for MDZ, and 6.1 and 5.7% for 1-OHMDZ at 0.3, 4, 20 and 40 ng/ml. The limits of quantification were 0.25 ng/ml for both MDZ and 1-OHMDZ. This method was sensitive and reliable enough for pharmacokinetic studies on healthy volunteers, and was applied for the measurement of CYP3A activity in humans after an intravenous (1 mg) and a single-oral administration (2 mg) of subtherapeutic MDZ dose.
AB - This paper describes sensitive and reliable determination of midazolam (MDZ) and its major metabolite 1′-hydroxymidazolam (1-OHMDZ) in human plasma by liquid chromatography-mass spectrometry (LC-MS) with a sonic spray ionization (SSI) interface. MDZ, 1-OHMDZ and diazepam as an internal standard were extracted from 1 ml of alkalinized plasma using n-hexane-chloroform (70:30, v/v). The extract was injected into an analytical column (YMC-Pak Pro C18, 50 mm × 2.0 mm i.d.). The mobile phase for separation consisted of 10 mM ammonium acetate and methanol (50:50, v/v) and was delivered at a flow-rate of 0.2 ml/min. The drift voltage was 100 V. The sampling aperture was heated at 120 °C and the shield temperature was 260 °C. The total time for chromatographic separation was less than 16 min. The validated concentration ranges of this method were 0.25-50 ng/ml for both MDZ and 1-OHMDZ. Mean recoveries were 93.6% for MDZ and 86.6% for 1-OHMDZ. Intra- and inter-day coefficient variations were less than 6.5 and 5.5% for MDZ, and 6.1 and 5.7% for 1-OHMDZ at 0.3, 4, 20 and 40 ng/ml. The limits of quantification were 0.25 ng/ml for both MDZ and 1-OHMDZ. This method was sensitive and reliable enough for pharmacokinetic studies on healthy volunteers, and was applied for the measurement of CYP3A activity in humans after an intravenous (1 mg) and a single-oral administration (2 mg) of subtherapeutic MDZ dose.
KW - 1′-Hydroxymidazolam
KW - CYP3A
KW - LC-MS
KW - Midazolam
UR - http://www.scopus.com/inward/record.url?scp=33847331529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33847331529&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2006.10.018
DO - 10.1016/j.jchromb.2006.10.018
M3 - Article
C2 - 17085083
AN - SCOPUS:33847331529
SN - 1570-0232
VL - 847
SP - 275
EP - 281
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 2
ER -