Skip to main navigation Skip to search Skip to main content

A selective dual-signal electrochemical paper-based device using imprinted sensors for voltammetric and impedance analysis of 4-NQO and carcinoembryonic antigen (CEA)

  • Pattanun Ngaosri
  • , Chanpen Karuwan
  • , Surasak Wanram
  • , Purim Jarujamrus
  • , Daniel Citterio
  • , Maliwan Amatatongchai

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Carcinoembryonic Antigen (CEA) and 4-nitroquinoline-N-oxide (4-NQO) are cancer markers that play a crucial role in tumor risk assessment and early cancer diagnosis. Therefore, it is in demand to develop a fast, accurate, simple, and cost-effective method to detect these cancer markers for quick and early stage-cancer diagnosis and treatment. Results: Herein, we report a dual signaling approach for direct and indirect signal transduction of cancer biomarker binding on molecularly imprinted-electrodes integrated on an ePAD, enabling sensitive and selective quantitative analysis of 4-NQO and CEA. Multiple test zones on a single device based on artificial recognition sites using core-shell Cu-MOF@MIP were developed to create a selective “Dual-signal-ePAD”. An effective and facile imprinting method on a Cu-MOF surface based on the synthesized of 4-VPBA/MAA/TRIM polymer. It resulted in a novel MIP useable as a high-performance sensing tool for the ultrasensitive and specific quantification of the target cancer biomarkers. Multiple tests consisted of voltammetric analysis of 4-NQO via oxidation of the analyte on a WE1, and impedance analysis of CEA via the molecular interaction with the imprinted WE2. Significance: The proposed device provides enhanced electrochemical signal amplification due to its high conductivity, electrocatalytic activity, and the target-specific recognition sites for accurate determination of 4-NQO and CEA targets. The Dual-signal-ePAD exhibits good voltammetric and EIS response, oxidation currents of 4-NQO at −0.06 V and RCT of CEA, resulting in high selectivity and sensitivity with a linear response range covering the concentration range of clinical interest for both analytes. Dual-signal ePAD is a good candidate for clinical screening and POCT.

Original languageEnglish
Article number343273
JournalAnalytica Chimica Acta
Volume1330
DOIs
Publication statusPublished - 2024 Nov 22

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Biomarkers
  • Colorectal cancer
  • Graphene screen-printed electrode
  • Metal–organic frameworks
  • Molecularly imprinted polymer
  • Point-of-care testing

ASJC Scopus subject areas

  • Analytical Chemistry
  • Environmental Chemistry
  • Biochemistry
  • Spectroscopy

Fingerprint

Dive into the research topics of 'A selective dual-signal electrochemical paper-based device using imprinted sensors for voltammetric and impedance analysis of 4-NQO and carcinoembryonic antigen (CEA)'. Together they form a unique fingerprint.

Cite this