T1 - Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes
AU - Gettinger, Kate
AU - Masui, Sachiko
AU - Omoto, Miki
AU - Torii, Hidemasa
AU - Yotsukura, Erisa
AU - Nishi, Yasuyo
AU - Ayaki, Masahiko
AU - Hayashi, Ken
AU - Negishi, Kazuno
N1 - Publisher Copyright:
© The Author(s) 2024.
PY - 2024/12
Y1 - 2024/12
N2 - This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated using nine formulas: Barrett True-K, Barrett True-K TK, Haigis-L, Haigis TK, Pearl-DGS, Hoffer QST, Hoffer QST PK, EVO K, and EVO PK. Statistical comparisons utilized Friedman test, Conover’s all-pairs post-hoc, Cochran’s Q, and McNemar post-hoc testing. Root-Mean-Square Error (RMSE) was compared with heteroscedastic testing. Barrett True-K TK had the lowest median predicted refractive error (-0.01). EVO PK had the smallest median absolute error (0.20). EVO PK had the highest percentage of eyes within ± 0.25 D of the predicted value (58.9%), significantly better than Haigis-L (p = 0.047). EVO PK had the lowest mean RMSE value (0.499). The EVO PK formula yielded the most accurate IOL power calculation in post-myopic LASIK eyes, with TK/PK values enhancing accuracy.
AB - This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated using nine formulas: Barrett True-K, Barrett True-K TK, Haigis-L, Haigis TK, Pearl-DGS, Hoffer QST, Hoffer QST PK, EVO K, and EVO PK. Statistical comparisons utilized Friedman test, Conover’s all-pairs post-hoc, Cochran’s Q, and McNemar post-hoc testing. Root-Mean-Square Error (RMSE) was compared with heteroscedastic testing. Barrett True-K TK had the lowest median predicted refractive error (-0.01). EVO PK had the smallest median absolute error (0.20). EVO PK had the highest percentage of eyes within ± 0.25 D of the predicted value (58.9%), significantly better than Haigis-L (p = 0.047). EVO PK had the lowest mean RMSE value (0.499). The EVO PK formula yielded the most accurate IOL power calculation in post-myopic LASIK eyes, with TK/PK values enhancing accuracy.
KW - IOL calculations
KW - IOL power calculation
KW - Post-LASIK IOL calculations
UR - http://www.scopus.com/inward/record.url?scp=85208492636&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85208492636&partnerID=8YFLogxK
U2 - 10.1038/s41598-024-78266-w
DO - 10.1038/s41598-024-78266-w
M3 - Article
C2 - 39489786
AN - SCOPUS:85208492636
SN - 2045-2322
VL - 14
JO - Scientific reports
JF - Scientific reports
IS - 1
M1 - 26560
ER -