TY - JOUR
T1 - Clinical Impact of Size, Shape, and Orientation of the Tricuspid Annulus in Tricuspid Regurgitation as Assessed by Three-Dimensional Echocardiography
AU - Utsunomiya, Hiroto
AU - Itabashi, Yuji
AU - Kobayashi, Sayuki
AU - Rader, Florian
AU - Siegel, Robert J.
AU - Shiota, Takahiro
N1 - Funding Information:
This work was partially supported by Merck Sharp and Dohme (MSD) Life Science Foundation, Public Interest Incorporated Foundation. This work was also supported by Takeda Science Foundation and Japan Society for the Promotion of Science Grants-in-Aid for Scientific Research (grant no. JP17K16008).
Publisher Copyright:
© 2019 American Society of Echocardiography
PY - 2020/2
Y1 - 2020/2
N2 - Background: Tricuspid annuloplasty for tricuspid regurgitation (TR) depends on the measurements of tricuspid annular diameter (TAD) obtained in an apical four-chamber view on two-dimensional (2D) transthoracic echocardiography (TTE). We performed a combined 2D and three-dimensional (3D) echocardiographic study to understand the impact of the size, shape, and orientation of a dilated annulus on the inconsistencies between measured 2D TTE-TAD and the actual annular diameter. Methods: A total of 185 patients with grade ≥3+ TR and 50 controls underwent 2D TTE and 3D transesophageal echocardiography (TEE) assessment of the tricuspid valve. The 3D TEE-TAD, defined as the longest dimension, and tricuspid annulus (TA) eccentricity index, defined as the shortest/longest dimension ratio, were obtained. The angle between the major tricuspid annulus axis and interatrial septum parallel to the vertical axis (α°) was measured as an index of TA orientation. Results: Compared with controls, TR subgroups had a larger α° irrespective of TR etiology and cardiac rhythm (P < .05), with the posteriorly displaced TA most frequently noted in patients with atrial fibrillation. An excellent correlation was found between 3D TEE-TAD and 2D TTE-TAD, but 2D TTE-TAD was significantly smaller than 3D TEE-TAD (35.9 ± 5.4 vs 39.8 ± 5.7 mm; P < .001; bias, 3.9 ± 2.6 mm; limits of agreement, −1.1-8.9 mm). After multivariate adjustment, a larger 3D TEE-TAD and larger absolute value of 90° − α° were independent determinants of the bias between 3D TEE-TAD and 2D TTE-TAD (both P < .001). Conclusions: The inconsistencies between measured 2D TTE-TAD and the actual annular diameter can be explained through morphologic factors such as TA size and orientation.
AB - Background: Tricuspid annuloplasty for tricuspid regurgitation (TR) depends on the measurements of tricuspid annular diameter (TAD) obtained in an apical four-chamber view on two-dimensional (2D) transthoracic echocardiography (TTE). We performed a combined 2D and three-dimensional (3D) echocardiographic study to understand the impact of the size, shape, and orientation of a dilated annulus on the inconsistencies between measured 2D TTE-TAD and the actual annular diameter. Methods: A total of 185 patients with grade ≥3+ TR and 50 controls underwent 2D TTE and 3D transesophageal echocardiography (TEE) assessment of the tricuspid valve. The 3D TEE-TAD, defined as the longest dimension, and tricuspid annulus (TA) eccentricity index, defined as the shortest/longest dimension ratio, were obtained. The angle between the major tricuspid annulus axis and interatrial septum parallel to the vertical axis (α°) was measured as an index of TA orientation. Results: Compared with controls, TR subgroups had a larger α° irrespective of TR etiology and cardiac rhythm (P < .05), with the posteriorly displaced TA most frequently noted in patients with atrial fibrillation. An excellent correlation was found between 3D TEE-TAD and 2D TTE-TAD, but 2D TTE-TAD was significantly smaller than 3D TEE-TAD (35.9 ± 5.4 vs 39.8 ± 5.7 mm; P < .001; bias, 3.9 ± 2.6 mm; limits of agreement, −1.1-8.9 mm). After multivariate adjustment, a larger 3D TEE-TAD and larger absolute value of 90° − α° were independent determinants of the bias between 3D TEE-TAD and 2D TTE-TAD (both P < .001). Conclusions: The inconsistencies between measured 2D TTE-TAD and the actual annular diameter can be explained through morphologic factors such as TA size and orientation.
KW - 3D echocardiography
KW - Transesophageal echocardiography
KW - Transthoracic echocardiography
KW - Tricuspid annular diameter
KW - Valvular heart disease
UR - http://www.scopus.com/inward/record.url?scp=85076491050&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85076491050&partnerID=8YFLogxK
U2 - 10.1016/j.echo.2019.09.016
DO - 10.1016/j.echo.2019.09.016
M3 - Article
C2 - 31837928
AN - SCOPUS:85076491050
SN - 0894-7317
VL - 33
SP - 191-200.e1
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 2
ER -