TY - JOUR
T1 - Cobalt-Chromium Alloy Has Superior Antibacterial Effect Than Titanium Alloy
T2 - In Vitro and In Vivo Studies
AU - Watanabe, Kota
AU - Fukuzaki, Satoshi
AU - Sugino, Atsushi
AU - Benson, Nicholas
AU - Metcalf, Newt
AU - Nakamura, Masaya
AU - Matsumoto, Morio
N1 - Publisher Copyright:
© 2021 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2021/9/1
Y1 - 2021/9/1
N2 - Study Design.In vitro and in vivo laboratory studies.Objective.This study aimed to compare bacterial survival on titanium alloy (Ti) and cobalt-chromium alloy (CC) using in vitro and in vivo experiments.Summary of Background Data.Spinal implants are frequently manufactured from Ti and CC. These foreign materials are thought to be susceptible to biofilm formation that contributes to the development of surgical site infections. Certain metals (i.e., silver, cobalt) are known to have antibacterial properties.Methods.In the in vitro study, discs made of Ti or CC were incubated with one of two common bacteria: Staphylococcus aureus (S. aureus) and Propionibacterium acnes (P. acnes). After incubation, discs were assessed to determine the number of viable bacterial cells. In the in vivo study, the discs that were made of CC or Ti were implanted into the subcutaneous layer of BALB/c mice. After skin closure, a suspension including either S. aureus or P. acnes was directly inoculated on the implanted discs. The discs were retrieved and analyzed to determine the number of viable bacteria at 0.5, 1, and 3 days after inoculation.Results.The number of viable S. aureus cultured from the CC discs was 0.9 ± 0.2 × 103 CFU/disc, which was significantly lower than the cultured Ti discs (114.8 ± 18.3 × 103 CFU/disc). Moreover, a significantly lower mean number of P. acnes were cultured with CC (1.9 ± 1.2 × 103 CFU/disc) compared with the Ti (180.0 ± 72.1 × 103 CFU/disc). The in vivo infection model testing against S. aureus or P. acnes showed a significantly lower number of viable S. aureus or P. acnes on CC discs than Ti discs. The result was seen at all measured time points.Conclusion.CC suppressed S. aureus and P. acnes proliferation compared with Ti in vitro and in an in vivo infection model.
AB - Study Design.In vitro and in vivo laboratory studies.Objective.This study aimed to compare bacterial survival on titanium alloy (Ti) and cobalt-chromium alloy (CC) using in vitro and in vivo experiments.Summary of Background Data.Spinal implants are frequently manufactured from Ti and CC. These foreign materials are thought to be susceptible to biofilm formation that contributes to the development of surgical site infections. Certain metals (i.e., silver, cobalt) are known to have antibacterial properties.Methods.In the in vitro study, discs made of Ti or CC were incubated with one of two common bacteria: Staphylococcus aureus (S. aureus) and Propionibacterium acnes (P. acnes). After incubation, discs were assessed to determine the number of viable bacterial cells. In the in vivo study, the discs that were made of CC or Ti were implanted into the subcutaneous layer of BALB/c mice. After skin closure, a suspension including either S. aureus or P. acnes was directly inoculated on the implanted discs. The discs were retrieved and analyzed to determine the number of viable bacteria at 0.5, 1, and 3 days after inoculation.Results.The number of viable S. aureus cultured from the CC discs was 0.9 ± 0.2 × 103 CFU/disc, which was significantly lower than the cultured Ti discs (114.8 ± 18.3 × 103 CFU/disc). Moreover, a significantly lower mean number of P. acnes were cultured with CC (1.9 ± 1.2 × 103 CFU/disc) compared with the Ti (180.0 ± 72.1 × 103 CFU/disc). The in vivo infection model testing against S. aureus or P. acnes showed a significantly lower number of viable S. aureus or P. acnes on CC discs than Ti discs. The result was seen at all measured time points.Conclusion.CC suppressed S. aureus and P. acnes proliferation compared with Ti in vitro and in an in vivo infection model.
KW - Propionibacterium acnes
KW - Staphylococcus aureus
KW - antibacterial
KW - antibacterial testing
KW - biomaterial
KW - cobalt-chromium alloy
KW - infection model
KW - spinal instrumentation
KW - surgical site infection
UR - http://www.scopus.com/inward/record.url?scp=85114101971&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85114101971&partnerID=8YFLogxK
U2 - 10.1097/BRS.0000000000003970
DO - 10.1097/BRS.0000000000003970
M3 - Article
C2 - 34384089
AN - SCOPUS:85114101971
SN - 0362-2436
VL - 46
SP - E911-E915
JO - Spine
JF - Spine
IS - 17
ER -