Originally received: August 14, 1991. Revision accepted: March 3, 1992. I Department of Ophthalmology, Tokyo Dental College, Chiba. 2 Department of Ophthalmology, Keio University School of Medicine, Tokyo. 3 Department of Ophthalmology, Tochigi National Hospital, Tochigi. Presented as a poster at the American Academy of Ophthalmology Annual Meeting, Atlanta, Oct/Nov 1990. Supported by the research grant of Japanese Government "Multicentered study on the complication of extended wear contact lens" and a grant from the Uehara Memorial Foundation, Tokyo, Japan.
PY - 1992
Y1 - 1992
N2 - Purpose: To study the effect of disposable extended-wear soft contact lenses on the corneal epithelium. Methods: Thirteen healthy patients (1 male, 12 females; average age, 26.3 ± 7.6 years) with or without histories of previous contact lens use were recruited for this study. Specular microscopic pictures of the corneal epithelium and endothelium were taken with the help of a specular contact lens, before and after 3 months of contact lens use. The pictures were analyzed by means of a computer-assisted morphometric analysis system. Results: The mean cell area and coefficient of variation (CV) of the mean cell area of the corneal epithelium before contact lens use were 639.4 ± 84.0 μum2 and 29.1 ± 13.2, respectively. After lens wear, the mean cell area increased to 819.7 ± 99.2 μM2 (P < 0.01), whereas the CV decreased to 20.0 ± 6.1 (P < 0.05). The corresponding values for the endothelium were 300.8 ± 22.5 μm2 and 36.4 ± 7.3 before contact lens use, and remained at 322.3 ± 27.8 μm2 and 32.8 ± 3.7 after contact lens use, respectively (P 〉 0.05). Conclusions: Based on the 3-month results, disposable extended-wear soft contact lenses caused similar enlargement of the mean cell area of the superficial corneal epithelium, as has been reported previously. It would appear that disposable lenses may cause the same metabolic and physiologic changes in the corneal epithelium as do conventional extended-wear soft contact lenses.
AB - Purpose: To study the effect of disposable extended-wear soft contact lenses on the corneal epithelium. Methods: Thirteen healthy patients (1 male, 12 females; average age, 26.3 ± 7.6 years) with or without histories of previous contact lens use were recruited for this study. Specular microscopic pictures of the corneal epithelium and endothelium were taken with the help of a specular contact lens, before and after 3 months of contact lens use. The pictures were analyzed by means of a computer-assisted morphometric analysis system. Results: The mean cell area and coefficient of variation (CV) of the mean cell area of the corneal epithelium before contact lens use were 639.4 ± 84.0 μum2 and 29.1 ± 13.2, respectively. After lens wear, the mean cell area increased to 819.7 ± 99.2 μM2 (P < 0.01), whereas the CV decreased to 20.0 ± 6.1 (P < 0.05). The corresponding values for the endothelium were 300.8 ± 22.5 μm2 and 36.4 ± 7.3 before contact lens use, and remained at 322.3 ± 27.8 μm2 and 32.8 ± 3.7 after contact lens use, respectively (P 〉 0.05). Conclusions: Based on the 3-month results, disposable extended-wear soft contact lenses caused similar enlargement of the mean cell area of the superficial corneal epithelium, as has been reported previously. It would appear that disposable lenses may cause the same metabolic and physiologic changes in the corneal epithelium as do conventional extended-wear soft contact lenses.
UR - http://www.scopus.com/inward/record.url?scp=0026756761&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026756761&partnerID=8YFLogxK
U2 - 10.1016/S0161-6420(92)31824-X
DO - 10.1016/S0161-6420(92)31824-X
M3 - Article
C2 - 1513570
AN - SCOPUS:0026756761
SN - 0161-6420
VL - 99
SP - 1193
EP - 1196
JO - Ophthalmology
JF - Ophthalmology
IS - 8
ER -