TY - JOUR
T1 - Decision-tree sensitivity analysis for cost-effectiveness of chest 2- fluoro-2-D-[18F]fluorodeoxyglucose positron emission tomography in patients with pulmonary nodules (non-small cell lung carcinoma) in Japan
AU - Kosuda, Shigeru
AU - Ichihara, Kiyoshi
AU - Watanabe, Masumi
AU - Kobayashi, Hideo
AU - Kusano, Shoichi
N1 - Funding Information:
Partially supported by funding from the Working Group Project of the Japanese Society of Nuclear Medicine.
PY - 2000
Y1 - 2000
N2 - Context: Recent studies have demonstrated the potential cost- effectiveness of using 2-fluoro-2D-[18F]fluorodeoxyglucose (FDG) positron emission tomography (PET) in the management of non-small cell lung carcinoma (NSCLC), but because of differences in health-care systems, those findings may not hold true in a Japanese hospital. Objective: To assess the cost- effectiveness of the chest CT plus chest FDG-PET strategy in Japan. Design: Decision-tree sensitivity analysis based on the two competing strategies of chest CT-alone vs chest CT plus chest FDG-PET. Study selection: A simulation of 1,000 patients in whom NSCLC, stage IIIB or less, was suspected was created using baselines of other relevant variables in regard to sensitivity, specificity, mortality, life expectancy, and cost from published data. Methods: We surveyed the relevant literature for the choice of variables. Main outcome measures: Expected marginal cost and expected life expectancy gain for NSCLC patients. Results: The chest CT plus chest FDG-PET strategy yielded an expected life expectancy gain of 0.607 years (7.3 months) per patient, compared with the alternative strategy of chest CT-alone. Using an FDG-PET examination cost of 1.0 x 105 yen (around $700 US) per study, the cost increment was 2.18 x 105 yen/yr/patient. Conclusions: The chest CT plus chest FDG-PET strategy in patients with NSCLC is unlikely to be cost- effective in Japan. However, patient life expectancy gain would increase as a result of improved staging of NSCLC. These preliminary results should be confirmed by further studies for specific environments.
AB - Context: Recent studies have demonstrated the potential cost- effectiveness of using 2-fluoro-2D-[18F]fluorodeoxyglucose (FDG) positron emission tomography (PET) in the management of non-small cell lung carcinoma (NSCLC), but because of differences in health-care systems, those findings may not hold true in a Japanese hospital. Objective: To assess the cost- effectiveness of the chest CT plus chest FDG-PET strategy in Japan. Design: Decision-tree sensitivity analysis based on the two competing strategies of chest CT-alone vs chest CT plus chest FDG-PET. Study selection: A simulation of 1,000 patients in whom NSCLC, stage IIIB or less, was suspected was created using baselines of other relevant variables in regard to sensitivity, specificity, mortality, life expectancy, and cost from published data. Methods: We surveyed the relevant literature for the choice of variables. Main outcome measures: Expected marginal cost and expected life expectancy gain for NSCLC patients. Results: The chest CT plus chest FDG-PET strategy yielded an expected life expectancy gain of 0.607 years (7.3 months) per patient, compared with the alternative strategy of chest CT-alone. Using an FDG-PET examination cost of 1.0 x 105 yen (around $700 US) per study, the cost increment was 2.18 x 105 yen/yr/patient. Conclusions: The chest CT plus chest FDG-PET strategy in patients with NSCLC is unlikely to be cost- effective in Japan. However, patient life expectancy gain would increase as a result of improved staging of NSCLC. These preliminary results should be confirmed by further studies for specific environments.
KW - 2-fluoro-2-D-[F]fluorodeoxyglucose positron emission tomography
KW - Cost-effectiveness
KW - Life expectancy non-small cell lung carcinoma
UR - http://www.scopus.com/inward/record.url?scp=0033999947&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033999947&partnerID=8YFLogxK
U2 - 10.1378/chest.117.2.346
DO - 10.1378/chest.117.2.346
M3 - Article
C2 - 10669673
AN - SCOPUS:0033999947
SN - 0012-3692
VL - 117
SP - 346
EP - 353
JO - Chest
JF - Chest
IS - 2
ER -