T1 - Determinatioii of anions with a potentiometric detector for ion chromatography
AU - Suzuki, Koji
AU - Aruga, Hiroshi
AU - Ishiwada, Hitoshi
AU - Oshima, Toyoko
AU - Inoue, Hidenari
AU - Shirai, Tsuneo
PY - 1983
Y1 - 1983
N2 - A potentiometric detector based on an ion-selective electrode (ISE) was constructed and used to determine anions by ion chromatography. The ISEs employed were two types : one is silver-silver halide electrodes (Ag-AgCl, Ag-AgBr, and Ag-AgI) and the other is an epoxy resin matrix electrode using trioctylmethyl-ammonium ion as sensing material. The detectors based on the former electrodes respond specifically to halide and pseudo-halide ions. In case of using CHaCOOH-CHaCOONa solution (2x10-3M, pH 6.4) as eluent, 6 species of anions (Cl-, Br-, I-, SGN-, GN-, and S-) could be detected down to 2x10-6M (100 p,l-injection) with a detector based on an Ag-AgCl electrode. On the other hand, a detector based on the latter electrode could determine more various anions. In particular, the detector was highly sensitive to NO2-, NO3-, CIO4-, I-, and SGN-. The detection limit for these ions was 5x10-5M at 100 jil-injection. The double column chromatography using separation and suppression columns with 5x 10-3 M NaOH solution as eluent was the most efficient system for the detection of anions with a detector based on an epoxy resin matrix electrode. Anions of NO2-, Br-, and NO3- could be detected down to lXlO-6M (100 p,l-injection). The sensitivities of most detectors constructed were kept constant for at least 2 months. The detector can be easily constructed with exchangeable detector assemblies including ISE, which is also prepared with ease. This provides an additional advantage to the detector.
AB - A potentiometric detector based on an ion-selective electrode (ISE) was constructed and used to determine anions by ion chromatography. The ISEs employed were two types : one is silver-silver halide electrodes (Ag-AgCl, Ag-AgBr, and Ag-AgI) and the other is an epoxy resin matrix electrode using trioctylmethyl-ammonium ion as sensing material. The detectors based on the former electrodes respond specifically to halide and pseudo-halide ions. In case of using CHaCOOH-CHaCOONa solution (2x10-3M, pH 6.4) as eluent, 6 species of anions (Cl-, Br-, I-, SGN-, GN-, and S-) could be detected down to 2x10-6M (100 p,l-injection) with a detector based on an Ag-AgCl electrode. On the other hand, a detector based on the latter electrode could determine more various anions. In particular, the detector was highly sensitive to NO2-, NO3-, CIO4-, I-, and SGN-. The detection limit for these ions was 5x10-5M at 100 jil-injection. The double column chromatography using separation and suppression columns with 5x 10-3 M NaOH solution as eluent was the most efficient system for the detection of anions with a detector based on an epoxy resin matrix electrode. Anions of NO2-, Br-, and NO3- could be detected down to lXlO-6M (100 p,l-injection). The sensitivities of most detectors constructed were kept constant for at least 2 months. The detector can be easily constructed with exchangeable detector assemblies including ISE, which is also prepared with ease. This provides an additional advantage to the detector.
KW - determination of anions by ion chromatography
KW - potentiometric detector based on ion-selective electrode
UR - http://www.scopus.com/inward/record.url?scp=85007965708&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85007965708&partnerID=8YFLogxK
U2 - 10.2116/bunsekikagaku.32.10_585
DO - 10.2116/bunsekikagaku.32.10_585
M3 - Article
AN - SCOPUS:85007965708
SN - 0525-1931
VL - 32
SP - 585
EP - 590
JO - BUNSEKI KAGAKU
JF - BUNSEKI KAGAKU
IS - 10
ER -