TY - JOUR
T1 - Electroencephalogram measurement using polymer-based dry microneedle electrode
AU - Arai, Miyako
AU - Nishinaka, Yuya
AU - Miki, Norihisa
N1 - Publisher Copyright:
© 2015 The Japan Society of Applied Physics.
PY - 2015/6/1
Y1 - 2015/6/1
N2 - In this paper, we report a successful electroencephalogram (EEG) measurement using polymer-based dry microneedle electrodes. The electrodes consist of needle-shaped substrates of SU-8, a silver film, and a nanoporous parylene protective film. Differently from conventional wet electrodes, microneedle electrodes do not require skin preparation and a conductive gel. SU-8 is superior as a structural material to poly(dimethylsiloxane) (PDMS; Dow Corning Toray Sylgard 184) in terms of hardness, which was used in our previous work, and facilitates the penetration of needles through the stratum corneum. SU-8 microneedles can be successfully inserted into the skin without breaking and could maintain a sufficiently low skin-electrode contact impedance for EEG measurement. The electrodes successfully measured EEG from the frontal pole, and the quality of acquired signals was verified to be as high as those obtained using commercially available wet electrodes without any skin preparation or a conductive gel. The electrodes are readily applicable to record brain activities for a long period with little stress involved in skin preparation to the users.
AB - In this paper, we report a successful electroencephalogram (EEG) measurement using polymer-based dry microneedle electrodes. The electrodes consist of needle-shaped substrates of SU-8, a silver film, and a nanoporous parylene protective film. Differently from conventional wet electrodes, microneedle electrodes do not require skin preparation and a conductive gel. SU-8 is superior as a structural material to poly(dimethylsiloxane) (PDMS; Dow Corning Toray Sylgard 184) in terms of hardness, which was used in our previous work, and facilitates the penetration of needles through the stratum corneum. SU-8 microneedles can be successfully inserted into the skin without breaking and could maintain a sufficiently low skin-electrode contact impedance for EEG measurement. The electrodes successfully measured EEG from the frontal pole, and the quality of acquired signals was verified to be as high as those obtained using commercially available wet electrodes without any skin preparation or a conductive gel. The electrodes are readily applicable to record brain activities for a long period with little stress involved in skin preparation to the users.
UR - http://www.scopus.com/inward/record.url?scp=84930715034&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84930715034&partnerID=8YFLogxK
U2 - 10.7567/JJAP.54.06FP14
DO - 10.7567/JJAP.54.06FP14
M3 - Article
AN - SCOPUS:84930715034
SN - 0021-4922
VL - 54
JO - Japanese journal of applied physics
JF - Japanese journal of applied physics
IS - 6
M1 - 06FP14
ER -