T1 - Evaluation of optical function using a new point spread function analysis system in cataractous and pseudophakic eyes
T2 - Preliminary results
AU - Negishi, Kazuno
AU - Kobayashi, Katsuhiko
AU - Ohnuma, Kazuhiko
AU - Ohno, Kenji
AU - Noda, Toru
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2006/1
Y1 - 2006/1
N2 - Purpose: To evaluate optical function in cataractous and pseudophakic eyes using the new point spread function (PSF) analysis system in a clinical setting. Methods: We applied this new analysis system in the study of two cataractous eyes and one pseudophakic eye of two patients. Using a PSF analyzer, double-pass PSF was measured directly for each subject, and the single-pass modulation transfer function (MTF) and single-pass PSF were calculated. The simulated retinal images of various sizes of Landolt's rings and their contrast characteristics were also calculated by the PSF analyzer. Results: The MTF and the contrast of the simulated retinal images degraded in cataractous eyes were compared with data for normal eyes; the degradation pattern depended on the opacification pattern. The MTF and the contrast of the simulated retinal images in the pseudophakic eye improved significantly compared with the cataractous eyes, although both values were lower in the pseudophakic eye than in young normal eyes. Conclusions: Our data showed degradation of optical function in cataractous and pseudophakic eyes in comparison with optical function in young normal eyes. If further accumulations of PSF data are made, it may be possible to establish an objective standard by which to measure the progression of cataract, as well as an objective indication for treatment in the future.
AB - Purpose: To evaluate optical function in cataractous and pseudophakic eyes using the new point spread function (PSF) analysis system in a clinical setting. Methods: We applied this new analysis system in the study of two cataractous eyes and one pseudophakic eye of two patients. Using a PSF analyzer, double-pass PSF was measured directly for each subject, and the single-pass modulation transfer function (MTF) and single-pass PSF were calculated. The simulated retinal images of various sizes of Landolt's rings and their contrast characteristics were also calculated by the PSF analyzer. Results: The MTF and the contrast of the simulated retinal images degraded in cataractous eyes were compared with data for normal eyes; the degradation pattern depended on the opacification pattern. The MTF and the contrast of the simulated retinal images in the pseudophakic eye improved significantly compared with the cataractous eyes, although both values were lower in the pseudophakic eye than in young normal eyes. Conclusions: Our data showed degradation of optical function in cataractous and pseudophakic eyes in comparison with optical function in young normal eyes. If further accumulations of PSF data are made, it may be possible to establish an objective standard by which to measure the progression of cataract, as well as an objective indication for treatment in the future.
KW - Cataract
KW - Intraocular lens
KW - Optical function
KW - Point spread function
UR - http://www.scopus.com/inward/record.url?scp=32044438228&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=32044438228&partnerID=8YFLogxK
U2 - 10.1007/s10384-005-0275-z
DO - 10.1007/s10384-005-0275-z
M3 - Article
C2 - 16453182
AN - SCOPUS:32044438228
SN - 0021-5155
VL - 50
SP - 12
EP - 19
JO - Japanese Journal of Ophthalmology
JF - Japanese Journal of Ophthalmology
IS - 1
ER -