TY - JOUR
T1 - Examination of formula for enhanced dynamic wedge factors in half fields
AU - Sato, Tomoharu
AU - Hanada, Takashi
AU - Ito, Yasushi
AU - Sasaki, Miwa
AU - Ootsuka, Tsugio
PY - 2006/3/20
Y1 - 2006/3/20
N2 - The method presented by Liu et al. in 1998 has generally been used in Japan to calculate the wedge factor of the enhanced dynamic wedge (EDW). When the points used to evaluate the dose exist outside the central beam axis in the half field (HF), however, a difference of about 3% can occur between the values calculated by this method and the measured values. In 2003, Liu et al. presented a new general formula for calculating MU using the EDW. We modified the formula for calculating the wedge factor by combining the conventional calculation formula and the formula of Liu et al., presented in 2003, and compared the calculated values of the wedge factor of the EDW in the HF with the measured values. Our formula employs a very simple method in which only the normalized golden segmented treatment table (NGSTT) on the center of the radiation field and the central beam axis are added to the existing formula. The values calculated by our formula and the measured values were consistent within 1% in most combinations of energy, wedge angle, and size of radiation field. When the EDW was used for irradiation to the tangent line of the HF breast, in particular, the values calculated by our formula and the measured values were consistent within 0.5%, and it was possible to calculate the wedge factor with a higher degree of accuracy than that calculated with the existing formula.
AB - The method presented by Liu et al. in 1998 has generally been used in Japan to calculate the wedge factor of the enhanced dynamic wedge (EDW). When the points used to evaluate the dose exist outside the central beam axis in the half field (HF), however, a difference of about 3% can occur between the values calculated by this method and the measured values. In 2003, Liu et al. presented a new general formula for calculating MU using the EDW. We modified the formula for calculating the wedge factor by combining the conventional calculation formula and the formula of Liu et al., presented in 2003, and compared the calculated values of the wedge factor of the EDW in the HF with the measured values. Our formula employs a very simple method in which only the normalized golden segmented treatment table (NGSTT) on the center of the radiation field and the central beam axis are added to the existing formula. The values calculated by our formula and the measured values were consistent within 1% in most combinations of energy, wedge angle, and size of radiation field. When the EDW was used for irradiation to the tangent line of the HF breast, in particular, the values calculated by our formula and the measured values were consistent within 0.5%, and it was possible to calculate the wedge factor with a higher degree of accuracy than that calculated with the existing formula.
UR - http://www.scopus.com/inward/record.url?scp=33646841346&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33646841346&partnerID=8YFLogxK
U2 - 10.6009/jjrt.62.409
DO - 10.6009/jjrt.62.409
M3 - Article
C2 - 16604046
AN - SCOPUS:33646841346
SN - 0369-4305
VL - 62
SP - 409
EP - 416
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
IS - 3
ER -