TY - JOUR
T1 - Fabrication process development and basic evaluation of eggshell-based column packing material for reversed-phase preparative separation
AU - Yoshii, Tomoka
AU - Sakama, Akihiro
AU - Kanamori, Kazuyoshi
AU - Nakanishi, Kazuki
AU - Imai, Hiroaki
AU - Citterio, Daniel
AU - Hiruta, Yuki
N1 - Funding Information:
This research is supported by Adaptable and Seamless Technology transfer Program through Target-driven R&D (A-STEP) from Japan Science and Technology Agency (JST) Grant Number JPMJTM20D7, Mizuho Foundation for the Promotion of Sciences, and Mukai Science and Technology Foundation. The authors thank Dr. Kei Morisato of Kyoto University for their support with mercury porosimetry.
Publisher Copyright:
© 2022 Elsevier B.V.
PY - 2023/1/11
Y1 - 2023/1/11
N2 - Purification of basic drugs in reversed-phase mode is often difficult, mainly due to adsorption of positively charged compounds to the silica gel-based stationary phase. Since this adsorption can be suppressed under alkaline condition, columns with alkali-resistance are required. In addition, compounds with acid-sensitive structures are sometimes degraded during separation on silica gel-based columns which exhibit acidity due to their surface structure. We prepared an alkali-resistant reversed-phase packing material, Eggshell-PMAcO based on eggshells modified with an amphiphilic copolymer, poly(maleic acid-alt-1-octadecene) (PMAcO). The height equivalent to a theoretical plate (HETP) of the Eggshell-PMAcO column was improved by surface treatment with ammonium acetate buffer (900 mM, pH = 3.7), which is an inexpensive reagent, and the retention behavior for hydrophobic compounds was compared to a typical ODS column based on silica gel, resulting in sufficient selectivity of the eggshell-based column for hydrophobic compounds, as indicated by the ratio of retention factors of pentylbenzene and butylbenzene (Eggshell-PMAcO column: 1.55, ODS column: 1.65). Column temperature-dependent retention behavior of naphthalene was investigated in the temperature range from 25 °C to 45 °C, followed by the calculation of thermodynamic parameters. There was little difference in the standard molar enthalpy (Eggshell-PMAcO: −19.6 kJ/mol, ODS: −21.7 kJ/mol). The absolute value of the standard free Gibbs energy for the Eggshell-PMAcO column was much smaller than that of the ODS column (Eggshell-PMAcO: −0.284 kJ/mol, ODS: −13.0 kJ/mol), indicating that the Eggshell-PMAcO column had a weaker retention strength for naphthalene than the ODS column mainly due to the large difference in the standard molar entropy (Eggshell-PMAcO: −64.9 J/mol K, ODS column: −29.2 J/mol K). The retention capacities for imipramine under neutral (water/methanol) and alkaline (0.1% triethylamine water/methanol) conditions were 0.2 mg and 5 mg, respectively, based on injection mass-dependent HETP, retention factor and symmetry factor. Finally, the prepared column was applied to the purification of a building block for nucleic acid drugs. This study demonstrated that reversed-phase columns, which can be fabricated from eggshells and an amphiphilic copolymer in an inexpensive and eco-friendly way, have the ability to purify basic compounds and acid-sensitive compounds.
AB - Purification of basic drugs in reversed-phase mode is often difficult, mainly due to adsorption of positively charged compounds to the silica gel-based stationary phase. Since this adsorption can be suppressed under alkaline condition, columns with alkali-resistance are required. In addition, compounds with acid-sensitive structures are sometimes degraded during separation on silica gel-based columns which exhibit acidity due to their surface structure. We prepared an alkali-resistant reversed-phase packing material, Eggshell-PMAcO based on eggshells modified with an amphiphilic copolymer, poly(maleic acid-alt-1-octadecene) (PMAcO). The height equivalent to a theoretical plate (HETP) of the Eggshell-PMAcO column was improved by surface treatment with ammonium acetate buffer (900 mM, pH = 3.7), which is an inexpensive reagent, and the retention behavior for hydrophobic compounds was compared to a typical ODS column based on silica gel, resulting in sufficient selectivity of the eggshell-based column for hydrophobic compounds, as indicated by the ratio of retention factors of pentylbenzene and butylbenzene (Eggshell-PMAcO column: 1.55, ODS column: 1.65). Column temperature-dependent retention behavior of naphthalene was investigated in the temperature range from 25 °C to 45 °C, followed by the calculation of thermodynamic parameters. There was little difference in the standard molar enthalpy (Eggshell-PMAcO: −19.6 kJ/mol, ODS: −21.7 kJ/mol). The absolute value of the standard free Gibbs energy for the Eggshell-PMAcO column was much smaller than that of the ODS column (Eggshell-PMAcO: −0.284 kJ/mol, ODS: −13.0 kJ/mol), indicating that the Eggshell-PMAcO column had a weaker retention strength for naphthalene than the ODS column mainly due to the large difference in the standard molar entropy (Eggshell-PMAcO: −64.9 J/mol K, ODS column: −29.2 J/mol K). The retention capacities for imipramine under neutral (water/methanol) and alkaline (0.1% triethylamine water/methanol) conditions were 0.2 mg and 5 mg, respectively, based on injection mass-dependent HETP, retention factor and symmetry factor. Finally, the prepared column was applied to the purification of a building block for nucleic acid drugs. This study demonstrated that reversed-phase columns, which can be fabricated from eggshells and an amphiphilic copolymer in an inexpensive and eco-friendly way, have the ability to purify basic compounds and acid-sensitive compounds.
KW - Amphiphilic copolymer
KW - Calcium carbonate
KW - Eggshell
KW - Purification
KW - Reversed-phase liquid chromatography
UR - http://www.scopus.com/inward/record.url?scp=85144608119&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144608119&partnerID=8YFLogxK
U2 - 10.1016/j.chroma.2022.463722
DO - 10.1016/j.chroma.2022.463722
M3 - Article
C2 - 36571981
AN - SCOPUS:85144608119
SN - 0021-9673
VL - 1688
JO - Journal of Chromatography A
JF - Journal of Chromatography A
M1 - 463722
ER -