TY - JOUR
T1 - Flow-through type calcium ion selective optodes based on novel neutral ionophores and a lipophilic anionic dye
AU - Hisamoto, Hideaki
AU - Watanabe, Kazuhiko
AU - Nakagawa, Eriko
AU - Siswanta, Dwi
AU - Shichi, Yushi
AU - Suzuki, Koji
N1 - Funding Information:
This work was partially supportedb y theA sahi Glass Foundation, &rata ResearchF und and Iketani Foundation.
PY - 1994/12/30
Y1 - 1994/12/30
N2 - Flow-through type calcium ion selective optodes based on novel neutral ionophores and a lipophilic anionic dye were developed. The novel calcium ion selective neutral ionophores designed and synthesized were double-armed diazacrown ether compounds possessing glycolic amides as the binding arms. Cation sensing material was prepared by coating pellicular-type ODS (octadecylsilica) beads with a lipophilic organic liquid which incorporates a novel neutral calcium ionophore and a lipophilic anionic dye of the diphenyl amine type. These beads were packed in a flow-through optical cell, and the Ca2+ measurement was performed to measure the absorbance change of the sensing beads at 516 nm. The best optode tested exhibited a good response to calcium ions in the concentration range from 10-7 M to 10-1 M with 0.05 M Tris-HCl of pH 7.0 as the flowing buffer solution. This optode showed excellent Ca2+ selectivity of over 10-4 in selectivity coefficient values (ki,jopt.; i = primary ion (Ca2+); j = interfering ion) against Na+, K+ and Mg2+ which are primary interferents for human serum analysis. Sensor response theory, response time, selectivity, and application to the determination of calcium ion concentration in human serum were also discussed together with experimental results.
AB - Flow-through type calcium ion selective optodes based on novel neutral ionophores and a lipophilic anionic dye were developed. The novel calcium ion selective neutral ionophores designed and synthesized were double-armed diazacrown ether compounds possessing glycolic amides as the binding arms. Cation sensing material was prepared by coating pellicular-type ODS (octadecylsilica) beads with a lipophilic organic liquid which incorporates a novel neutral calcium ionophore and a lipophilic anionic dye of the diphenyl amine type. These beads were packed in a flow-through optical cell, and the Ca2+ measurement was performed to measure the absorbance change of the sensing beads at 516 nm. The best optode tested exhibited a good response to calcium ions in the concentration range from 10-7 M to 10-1 M with 0.05 M Tris-HCl of pH 7.0 as the flowing buffer solution. This optode showed excellent Ca2+ selectivity of over 10-4 in selectivity coefficient values (ki,jopt.; i = primary ion (Ca2+); j = interfering ion) against Na+, K+ and Mg2+ which are primary interferents for human serum analysis. Sensor response theory, response time, selectivity, and application to the determination of calcium ion concentration in human serum were also discussed together with experimental results.
KW - Calcium
KW - Ion-selective electrodes
KW - Lipophilic anionic dye
KW - Neutral ionophores
UR - http://www.scopus.com/inward/record.url?scp=0028593556&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028593556&partnerID=8YFLogxK
U2 - 10.1016/0003-2670(94)00351-3
DO - 10.1016/0003-2670(94)00351-3
M3 - Article
AN - SCOPUS:0028593556
SN - 0003-2670
VL - 299
SP - 179
EP - 187
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
IS - 2
ER -