TY - JOUR
T1 - Inductively coupled plasma mass spectrometry for the sequential determination of trace metals in sea water after electrothermal vaporization of their dithiocarmabamate complexes in methyl isobuthyl ketone
AU - Santosa, Sri Juari
AU - Tanaka, Shigeru
AU - Yamanaka, Kazuo
PY - 1997/1/1
Y1 - 1997/1/1
N2 - A sensitive method has been developed for the sequential determination of V, Mn, Fe, Co, Ni, Cu, Zn, Mo and Sb in sea water using inductively coupled plasma mass spectrometry (ICP-MS) after electrothermal vaporization of their dithiocarbamate complexes in methyl isobutyl ketone (MIBK). After complexion with sodium diethyldithiocarbamate (NaDDTC), all trace analyte elements were simultaneously separated from sea water matrix and concentrated 20 fold in a single extract of MIBK, followed by introduction of 10 μL of the extract into argon plasma using a pyrolytic graphite rod electrothermal vaporizer (ETV). Sensitivity enhancement due to chemical modification using a mixed modifier of Pd(NO3)2-Mg(NO3)2 was observed for all the elements. The limits of detection ranged from 2 ng/L for Co to 329 ng/L for V. For replicate determinations of the elements in sea water, the repeatability was within 10% (as a coefficient variation), except for V (12.8%). The recovery test performed on a sea water sample resulted in a range value from 87% for Sb to 119% for V. The method has been successfully applied to sea water samples collected from the surface to the depth of 5000 m at a sampling station in the northwest Pacific Ocean.
AB - A sensitive method has been developed for the sequential determination of V, Mn, Fe, Co, Ni, Cu, Zn, Mo and Sb in sea water using inductively coupled plasma mass spectrometry (ICP-MS) after electrothermal vaporization of their dithiocarbamate complexes in methyl isobutyl ketone (MIBK). After complexion with sodium diethyldithiocarbamate (NaDDTC), all trace analyte elements were simultaneously separated from sea water matrix and concentrated 20 fold in a single extract of MIBK, followed by introduction of 10 μL of the extract into argon plasma using a pyrolytic graphite rod electrothermal vaporizer (ETV). Sensitivity enhancement due to chemical modification using a mixed modifier of Pd(NO3)2-Mg(NO3)2 was observed for all the elements. The limits of detection ranged from 2 ng/L for Co to 329 ng/L for V. For replicate determinations of the elements in sea water, the repeatability was within 10% (as a coefficient variation), except for V (12.8%). The recovery test performed on a sea water sample resulted in a range value from 87% for Sb to 119% for V. The method has been successfully applied to sea water samples collected from the surface to the depth of 5000 m at a sampling station in the northwest Pacific Ocean.
UR - http://www.scopus.com/inward/record.url?scp=0006383516&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0006383516&partnerID=8YFLogxK
U2 - 10.1007/s002160050317
DO - 10.1007/s002160050317
M3 - Article
AN - SCOPUS:0006383516
SN - 0937-0633
VL - 357
SP - 1122
EP - 1127
JO - Fresenius' Journal of Analytical Chemistry
JF - Fresenius' Journal of Analytical Chemistry
IS - 8
ER -