TY - JOUR
T1 - Intra-Articular Corrective Osteotomy for Distal Radial Intra-Articular Malunion Using Patient-Matched Instruments
T2 - A Prospective, Multicenter, Open-Label, Single-Arm Trial
AU - Oka, Kunihiro
AU - Miyamura, Satoshi
AU - Shiode, Ryoya
AU - Tanaka, Hiroyuki
AU - Iwasaki, Norimasa
AU - Kawamura, Daisuke
AU - Sato, Kazuki
AU - Iwamoto, Takuji
AU - Yamamoto, Michiro
AU - Nishida, Keiichiro
AU - Shimamura, Yasunori
AU - Yamada, Tomomi
AU - Okada, Seiji
AU - Murase, Tsuyoshi
N1 - Publisher Copyright:
Copyright © 2024 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved.
PY - 2024/8/19
Y1 - 2024/8/19
N2 - Background:Corrective osteotomy for intra-articular malunion is a challenging procedure. However, recent advancements, including patient-matched instruments created on the basis of preoperative computer simulation, enable accurate intra-articular correction. We hypothesized that intra-articular corrective osteotomy using patient-matched instruments for the treatment of distal radial intra-articular malunion would reduce intra-articular deformity and restore wrist function at 12 months of follow-up.Methods:This prospective study included 12 patients with distal radial intra-articular malunion who underwent intra-articular corrective osteotomy external to the joint using patient-matched instruments. The primary end point was the maximum step-off on the articular surface of the distal radius, measured with use of computed tomography (CT), with an expected postoperative value of ≤1.5 mm. The secondary end points included the gap of the articular surface; range of motion; grip strength; pain evaluated using a visual analog scale (VAS); patient satisfaction; Disabilities of the Arm, Shoulder and Hand (DASH) score; and Patient-Rated Wrist Evaluation (PRWE) score. A mean postoperative step-off of ≤1.5 mm for the primary end point was assessed with use of the 1-sample t test. The secondary end points were assessed with use of the Dunnett multiple comparison test.Results:The average step-off significantly improved from 3.75 ± 1.04 mm preoperatively to 0.51 ± 0.40 mm at the 52-week postoperative follow-up and was maintained within 1.5 mm. The average wrist and forearm range of motion, VAS score, grip strength, DASH score, and PRWE score significantly improved. Eleven patients were either very satisfied or satisfied with their outcomes.Conclusions:The use of patient-matched instruments could contribute to improving postoperative outcomes of intra-articular corrective osteotomy procedures involving the distal radius.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
AB - Background:Corrective osteotomy for intra-articular malunion is a challenging procedure. However, recent advancements, including patient-matched instruments created on the basis of preoperative computer simulation, enable accurate intra-articular correction. We hypothesized that intra-articular corrective osteotomy using patient-matched instruments for the treatment of distal radial intra-articular malunion would reduce intra-articular deformity and restore wrist function at 12 months of follow-up.Methods:This prospective study included 12 patients with distal radial intra-articular malunion who underwent intra-articular corrective osteotomy external to the joint using patient-matched instruments. The primary end point was the maximum step-off on the articular surface of the distal radius, measured with use of computed tomography (CT), with an expected postoperative value of ≤1.5 mm. The secondary end points included the gap of the articular surface; range of motion; grip strength; pain evaluated using a visual analog scale (VAS); patient satisfaction; Disabilities of the Arm, Shoulder and Hand (DASH) score; and Patient-Rated Wrist Evaluation (PRWE) score. A mean postoperative step-off of ≤1.5 mm for the primary end point was assessed with use of the 1-sample t test. The secondary end points were assessed with use of the Dunnett multiple comparison test.Results:The average step-off significantly improved from 3.75 ± 1.04 mm preoperatively to 0.51 ± 0.40 mm at the 52-week postoperative follow-up and was maintained within 1.5 mm. The average wrist and forearm range of motion, VAS score, grip strength, DASH score, and PRWE score significantly improved. Eleven patients were either very satisfied or satisfied with their outcomes.Conclusions:The use of patient-matched instruments could contribute to improving postoperative outcomes of intra-articular corrective osteotomy procedures involving the distal radius.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
UR - http://www.scopus.com/inward/record.url?scp=85201777408&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85201777408&partnerID=8YFLogxK
U2 - 10.2106/JBJS.OA.24.00026
DO - 10.2106/JBJS.OA.24.00026
M3 - Article
AN - SCOPUS:85201777408
SN - 2472-7245
VL - 9
JO - JBJS Open Access
JF - JBJS Open Access
IS - 3
M1 - e24.00026
ER -