T1 - Optimum displacement of muscle in relation to thickness for biceps brachii hardness measurement using a push-in meter
AU - Murayama, Mitsuyoshi
AU - Inami, Takayuki
AU - Shima, Norihiro
AU - Nosaka, Kazunori
AU - Uchiyama, Takanori
AU - Yoneda, Tsugutake
N1 - Publisher Copyright:
© 2018 IOP Publishing Ltd.
PY - 2019/1
Y1 - 2019/1
N2 - Objective: Muscle hardness measured by a push-in meter is calculated from a force-displacement curve (FDC) based on a two-layer spring model. Since a FDC is not linear, how to set a linear range in the FDC largely affects muscle hardness calculation. The present study investigated the linearity of the FDC to find the best portion relative to muscle thickness (MT) for muscle hardness measurement based on a two-layer spring model. Approach: Forty-seven men (age: 28 ±10 years, height: 176 ±7 cm, body mass: 73 ±11 kg) participated in the present study. Hardness of the biceps brachii muscle was measured at the mid-belly using a push-in meter. The FDC was obtained every 5% up to 50% of the MT, and linear regression equations of ten different portions within the FDC were calculated. The coefficient of determination (R 2 ) of each regression line was compared by ANOVA, and a piecewise linear regression analysis was performed by dividing the identified FDC into three linear segments. Results: One-way ANOVA showed a significant (p < 0.01) main effect in R 2 values of ten regression equations. Post-hoc analyses showed no significant differences in R 2 between 0%-15% MT and 0%-40% MT. While the linearity of the FDC was high between 0%-15% and 0%-40% MT, the highest R 2 value was found at 0%-25% and 0%-30% MT. According to the analysis of three linear segments in the FDC, the mean value of the point between the second and third segments was 28.5 ±4.3% MT. Significance: These results suggested that muscle hardness assessment using a push-in meter should be performed close to 30% MT depth for biceps brachii muscle.
AB - Objective: Muscle hardness measured by a push-in meter is calculated from a force-displacement curve (FDC) based on a two-layer spring model. Since a FDC is not linear, how to set a linear range in the FDC largely affects muscle hardness calculation. The present study investigated the linearity of the FDC to find the best portion relative to muscle thickness (MT) for muscle hardness measurement based on a two-layer spring model. Approach: Forty-seven men (age: 28 ±10 years, height: 176 ±7 cm, body mass: 73 ±11 kg) participated in the present study. Hardness of the biceps brachii muscle was measured at the mid-belly using a push-in meter. The FDC was obtained every 5% up to 50% of the MT, and linear regression equations of ten different portions within the FDC were calculated. The coefficient of determination (R 2 ) of each regression line was compared by ANOVA, and a piecewise linear regression analysis was performed by dividing the identified FDC into three linear segments. Results: One-way ANOVA showed a significant (p < 0.01) main effect in R 2 values of ten regression equations. Post-hoc analyses showed no significant differences in R 2 between 0%-15% MT and 0%-40% MT. While the linearity of the FDC was high between 0%-15% and 0%-40% MT, the highest R 2 value was found at 0%-25% and 0%-30% MT. According to the analysis of three linear segments in the FDC, the mean value of the point between the second and third segments was 28.5 ±4.3% MT. Significance: These results suggested that muscle hardness assessment using a push-in meter should be performed close to 30% MT depth for biceps brachii muscle.
KW - coefficient of determination
KW - muscle thickness
KW - piecewise linear regression analysis
KW - two-layer spring model
UR - http://www.scopus.com/inward/record.url?scp=85062880457&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062880457&partnerID=8YFLogxK
U2 - 10.1088/2057-1976/aaea52
DO - 10.1088/2057-1976/aaea52
M3 - Article
AN - SCOPUS:85062880457
SN - 2057-1976
VL - 5
JO - Biomedical Physics and Engineering Express
JF - Biomedical Physics and Engineering Express
IS - 1
M1 - 017001
ER -