TY - JOUR
T1 - Performance of Gd-EOB-DTPA and superparamagnetic iron oxide particles in the detection of primary liver cancer
T2 - A comparative study by alternative free-response receiver operating characteristic analysis
AU - Tanimoto, Akihiro
AU - Satoh, Yoshinori
AU - Yuasa, Yuji
AU - Jinzaki, Masahiro
AU - Hiramatsu, Kyoichi
PY - 1997
Y1 - 1997
N2 - The performance of gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the locations of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor-liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1WI. There was no Ai difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.
AB - The performance of gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the locations of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor-liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1WI. There was no Ai difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.
KW - Contrast media, gadolinium, iron, magnetic resonance
KW - Diagnosis, magnetic resonance
KW - Experimental, liver
KW - Magnetic resonance
KW - Neoplasm
UR - http://www.scopus.com/inward/record.url?scp=0031421927&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031421927&partnerID=8YFLogxK
U2 - 10.1002/jmri.1880070116
DO - 10.1002/jmri.1880070116
M3 - Article
C2 - 9039601
AN - SCOPUS:0031421927
SN - 1053-1807
VL - 7
SP - 120
EP - 124
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 1
ER -