TY - JOUR
T1 - Pleuroscopic punch biopsy using insulated-tip diathermic knife-2 for the diagnosis of desmoplastic malignant mesothelioma
AU - Masai, Kyohei
AU - Sasada, Shinji
AU - Izumo, Takehiro
AU - Taniyama, Tomoko
AU - Nakamura, Yukiko
AU - Chavez, Christine
AU - Sakurai, Hiroyuki
AU - Tsuta, Koji
AU - Tsuchida, Takaaki
PY - 2013/10
Y1 - 2013/10
N2 - Summary: Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.
AB - Summary: Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.
KW - Desmoplastic malignant mesothelioma
KW - Flex-rigid pleuroscope
KW - Full-thickness pleura
KW - Insulated-tip diathermic knife-2
KW - Pleuroscopic punch biopsy
UR - http://www.scopus.com/inward/record.url?scp=84887936987&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84887936987&partnerID=8YFLogxK
U2 - 10.1097/LBR.0000000000000010
DO - 10.1097/LBR.0000000000000010
M3 - Article
C2 - 24162121
AN - SCOPUS:84887936987
SN - 1944-6586
VL - 20
SP - 345
EP - 348
JO - Journal of Bronchology and Interventional Pulmonology
JF - Journal of Bronchology and Interventional Pulmonology
IS - 4
ER -