T1 - Practical guidelines of online MR-guided adaptive radiotherapy
AU - Okamoto, Hiroyuki
AU - Igaki, Hiroshi
AU - Chiba, Takahito
AU - Shibuya, Keiko
AU - Sakasai, Tatsuya
AU - Jingu, Keiichi
AU - Inaba, Koji
AU - Kuroda, Kagayaki
AU - Aoki, Shigeki
AU - Tatsumi, Daisaku
AU - Nakamura, Mitsuhiro
AU - Kadoya, Noriyuki
AU - Furuyama, Yoshinobu
AU - Kumazaki, Yu
AU - Tohyama, Naoki
AU - Tsuneda, Masato
AU - Nishioka, Shie
AU - Itami, Jun
AU - Onishi, Hiroshi
AU - Shigematsu, Naoyuki
AU - Uno, Takashi
N1 - Publisher Copyright:
© The Author(s) 2022. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
PY - 2022/9/21
Y1 - 2022/9/21
N2 - The first magnetic resonance (MR)-guided radiotherapy system in Japan was installed in May 2017. Implementation of online MR-guided adaptive radiotherapy (MRgART) began in February 2018. Online MRgART offers greater treatment accuracy owing to the high soft-tissue contrast in MR-images (MRI), compared to that in X-ray imaging. The Japanese Society for Magnetic Resonance in Medicine (JSMRM), Japan Society of Medical Physics (JSMP), Japan Radiological Society (JRS), Japanese Society of Radiological Technology (JSRT), and Japanese Society for Radiation Oncology (JASTRO) jointly established the comprehensive practical guidelines for online MRgART. These guidelines propose the essential requirements for clinical implementation of online MRgART with respect to equipment, personnel, institutional environment, practice guidance, and quality assurance/quality control (QA/QC). The minimum requirements for related equipment and QA/QC tools, recommendations for safe operation of MRI system, and the implementation system are described. The accuracy of monitor chamber and detector in dose measurements should be confirmed because of the presence of magnetic field. The ionization chamber should be MR-compatible. Non-MR-compatible devices should be used in an area that is not affected by the static magnetic field (outside the five Gauss line), and their operation should be checked to ensure that they do not affect the MR image quality. Dose verification should be performed using an independent dose verification system that has been confirmed to be reliable through commissioning. This guideline proposes the checklists to ensure the safety of online MRgART. Successful clinical implementation of online MRgART requires close collaboration between physician, radiological technologist, nurse, and medical physicist.
AB - The first magnetic resonance (MR)-guided radiotherapy system in Japan was installed in May 2017. Implementation of online MR-guided adaptive radiotherapy (MRgART) began in February 2018. Online MRgART offers greater treatment accuracy owing to the high soft-tissue contrast in MR-images (MRI), compared to that in X-ray imaging. The Japanese Society for Magnetic Resonance in Medicine (JSMRM), Japan Society of Medical Physics (JSMP), Japan Radiological Society (JRS), Japanese Society of Radiological Technology (JSRT), and Japanese Society for Radiation Oncology (JASTRO) jointly established the comprehensive practical guidelines for online MRgART. These guidelines propose the essential requirements for clinical implementation of online MRgART with respect to equipment, personnel, institutional environment, practice guidance, and quality assurance/quality control (QA/QC). The minimum requirements for related equipment and QA/QC tools, recommendations for safe operation of MRI system, and the implementation system are described. The accuracy of monitor chamber and detector in dose measurements should be confirmed because of the presence of magnetic field. The ionization chamber should be MR-compatible. Non-MR-compatible devices should be used in an area that is not affected by the static magnetic field (outside the five Gauss line), and their operation should be checked to ensure that they do not affect the MR image quality. Dose verification should be performed using an independent dose verification system that has been confirmed to be reliable through commissioning. This guideline proposes the checklists to ensure the safety of online MRgART. Successful clinical implementation of online MRgART requires close collaboration between physician, radiological technologist, nurse, and medical physicist.
KW - Magnetic resonance (MR)-guided
KW - adaptive radiotherapy (ART)
KW - quality assurance/quality control (QA/QC)
UR - http://www.scopus.com/inward/record.url?scp=85138305970&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85138305970&partnerID=8YFLogxK
U2 - 10.1093/jrr/rrac048
DO - 10.1093/jrr/rrac048
M3 - Article
C2 - 35946325
AN - SCOPUS:85138305970
SN - 0449-3060
VL - 63
SP - 730
EP - 740
JO - Journal of radiation research
JF - Journal of radiation research
IS - 5
ER -