TY - JOUR
T1 - Recovery functions of somatosensory vertex potentials in man
T2 - interaction of evoked responses from right and left fingers
AU - Okajima, Yasutomo
AU - Chino, Naoichi
AU - Saitoh, Eiichi
AU - Kimura, Akio
PY - 1991/1/1
Y1 - 1991/1/1
N2 - Somatosensory vertex potentials (SVPs) were examined in 12 healthy subjects in response to painful electrical stimulation of the finger. SVPs consisted of N1, P1, and N2. The average latencies of the 3 peaks were 150, 225, and 350 msec, respectively. The latency and amplitude of each potential were reproducible for each subject. Recovery functions of the SVPs were analyzed in 10 subjects. A pair of stimuli were delivered to the right or left finger with interstimulus intervals (ISIs) of 50, 100, 150, 200, 350, 500 and 650 msec. SVPs partially recovered with the shortest ISI (50 msec). Full recovery could not be obtained even with the longest ISI (650 msec). Differences in recoveries within 650 msec of ISI were not observed between right and left stimulations. To examine the interaction between SVPs evoked by right and left finger stimulation, recovery functions from prior contralateral finger stimulation were analyzed with the same ISIs. SVP recoveries for right after left or left after right patterns of stimulus delivery were nearly the same as those for ipsilateral ones. It is suggested that SVPs are generated at nearly the same site in the sensory pathway regardless of the side stimulated.
AB - Somatosensory vertex potentials (SVPs) were examined in 12 healthy subjects in response to painful electrical stimulation of the finger. SVPs consisted of N1, P1, and N2. The average latencies of the 3 peaks were 150, 225, and 350 msec, respectively. The latency and amplitude of each potential were reproducible for each subject. Recovery functions of the SVPs were analyzed in 10 subjects. A pair of stimuli were delivered to the right or left finger with interstimulus intervals (ISIs) of 50, 100, 150, 200, 350, 500 and 650 msec. SVPs partially recovered with the shortest ISI (50 msec). Full recovery could not be obtained even with the longest ISI (650 msec). Differences in recoveries within 650 msec of ISI were not observed between right and left stimulations. To examine the interaction between SVPs evoked by right and left finger stimulation, recovery functions from prior contralateral finger stimulation were analyzed with the same ISIs. SVP recoveries for right after left or left after right patterns of stimulus delivery were nearly the same as those for ipsilateral ones. It is suggested that SVPs are generated at nearly the same site in the sensory pathway regardless of the side stimulated.
KW - Interaction
KW - Neural pathways
KW - Recovery function
KW - Somatosensory evoked potentials
KW - Vertex potentials
UR - http://www.scopus.com/inward/record.url?scp=0025990854&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025990854&partnerID=8YFLogxK
U2 - 10.1016/0168-5597(91)90135-K
DO - 10.1016/0168-5597(91)90135-K
M3 - Article
C2 - 1720729
AN - SCOPUS:0025990854
SN - 0168-5597
VL - 80
SP - 531
EP - 535
JO - Electroencephalography and Clinical Neurophysiology/ Evoked Potentials
JF - Electroencephalography and Clinical Neurophysiology/ Evoked Potentials
IS - 6
ER -