TY - JOUR
T1 - Reference data for the thermal conductivity of saturated liquid toluene over a wide range of temperatures
AU - Ramires, Maria L.V.
AU - Nieto De Castro, Carlos A.
AU - Perkins, Richard A.
AU - Nagasaka, Yuchi
AU - Nagashima, Akira
AU - Assael, Marc J.
AU - Wakeham, William A.
PY - 2000
Y1 - 2000
N2 - Efficient design of industrial processes and equipment requires accurate thermal conductivity data for a variety of fluids, such as alternative refrigerants, fuels, petrochemicals, aqueous systems, molten salts, and molten metals. The accuracy of experimental thermal conductivity data is a function of the operating conditions of the instrument. Reference data are required over a wide range of conditions to verify the claimed uncertainties of absolute instruments and to calibrate relative instruments, since either type may be used to measure the thermal conductivity of fluids. Recently, accurate experimental data for the thermal conductivity of liquid toluene near the saturation line have been obtained, which allow the upper temperature limit of the previous reference-data correlation to be extended from 360 to 553 K. The thermal conductivity was measured using two transient hot-wire instruments from 300 to 550 K, the first with a bare 12.7 μm platinum wire and the second using an anodized 25 μm tantalum wire. Uncertainties due to the contribution of thermal radiation and the purity of the samples are discussed. The proposed value of the thermal conductivity of liquid toluene at 298.15 K and 0.1 MPa is 0.13 088 ± 0.000 85. The quality of the data is such that new improved recommendations and recommended values can be proposed with uncertainties at 95% confidence of 1% for 189 <T< 440 K, 1.5% for 440 <T< 480 K, and 2% for 480 <T< 553 K, near the saturation line.
AB - Efficient design of industrial processes and equipment requires accurate thermal conductivity data for a variety of fluids, such as alternative refrigerants, fuels, petrochemicals, aqueous systems, molten salts, and molten metals. The accuracy of experimental thermal conductivity data is a function of the operating conditions of the instrument. Reference data are required over a wide range of conditions to verify the claimed uncertainties of absolute instruments and to calibrate relative instruments, since either type may be used to measure the thermal conductivity of fluids. Recently, accurate experimental data for the thermal conductivity of liquid toluene near the saturation line have been obtained, which allow the upper temperature limit of the previous reference-data correlation to be extended from 360 to 553 K. The thermal conductivity was measured using two transient hot-wire instruments from 300 to 550 K, the first with a bare 12.7 μm platinum wire and the second using an anodized 25 μm tantalum wire. Uncertainties due to the contribution of thermal radiation and the purity of the samples are discussed. The proposed value of the thermal conductivity of liquid toluene at 298.15 K and 0.1 MPa is 0.13 088 ± 0.000 85. The quality of the data is such that new improved recommendations and recommended values can be proposed with uncertainties at 95% confidence of 1% for 189 <T< 440 K, 1.5% for 440 <T< 480 K, and 2% for 480 <T< 553 K, near the saturation line.
KW - High temperature
KW - Reference data
KW - Saturated liquid
KW - Thermal conductivity
KW - Toluene
UR - http://www.scopus.com/inward/record.url?scp=0040184275&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0040184275&partnerID=8YFLogxK
U2 - 10.1063/1.556057
DO - 10.1063/1.556057
M3 - Article
AN - SCOPUS:0040184275
SN - 0047-2689
VL - 29
SP - 133
EP - 139
JO - Journal of Physical and Chemical Reference Data
JF - Journal of Physical and Chemical Reference Data
IS - 2
ER -