TY - JOUR
T1 - Reference intervals and discrimination values of the Lanthony desaturated D-15 panel test in young to middle-aged Japanese army officials
T2 - The Okubo Color Study Report 1
AU - Shoji, T.
AU - Sakurai, Y.
AU - Chihara, E.
AU - Nishikawa, S.
AU - Omae, K.
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2009/6
Y1 - 2009/6
N2 - Purpose: To better understand the reference values and adequate discrimination values of colour vision function with described quantitative systems for the Lanthony desaturated D-15 panel (D-15DS).MethodsA total of 1042 Japanese male officials were interviewed and underwent testing using Ishihara pseudoisochromatic plates, standard pseudoisochromatic plates part 2, and the D-15DS. The Farnsworth-Munsell (F-M) 100-hue test and the criteria of Verriest et al were used as definitive tests. Outcomes of the D-15DS were calculated using Bowman's Colour Confusion Index (CCI). The study design included two criteria. In criterion A, subjects with current or past ocular disease and a best-corrected visual acuity less than 0.7 on a decimal visual acuity chart were excluded. In criterion B, among subjects who satisfied criterion A, those who had a congenital colour sense anomaly were excluded.ResultsOverall, the 90th percentile (95th percentile) CCI values for criteria A and B in the worse eye were 1.70 (1.95) and 1.59 (1.73), respectively. In subjects satisfying criterion B, the area under the receiver operating characteristic curve was 0.951 (95% confidence interval, 0.931-0.971). The CCI discrimination values of 1.52 or 1.63 showed 90.3% sensitivity and 90% specificity, or 71.5% sensitivity and 95% specificity, respectively, for discriminating acquired colour vision impairment (ACVI).ConclusionWe provided the 90th and 95th percentiles in a young to middle-aged healthy population. The CCI is in good agreement with the diagnosis of ACVI. Our results could be helpful for using D-15DS for screening purposes.
AB - Purpose: To better understand the reference values and adequate discrimination values of colour vision function with described quantitative systems for the Lanthony desaturated D-15 panel (D-15DS).MethodsA total of 1042 Japanese male officials were interviewed and underwent testing using Ishihara pseudoisochromatic plates, standard pseudoisochromatic plates part 2, and the D-15DS. The Farnsworth-Munsell (F-M) 100-hue test and the criteria of Verriest et al were used as definitive tests. Outcomes of the D-15DS were calculated using Bowman's Colour Confusion Index (CCI). The study design included two criteria. In criterion A, subjects with current or past ocular disease and a best-corrected visual acuity less than 0.7 on a decimal visual acuity chart were excluded. In criterion B, among subjects who satisfied criterion A, those who had a congenital colour sense anomaly were excluded.ResultsOverall, the 90th percentile (95th percentile) CCI values for criteria A and B in the worse eye were 1.70 (1.95) and 1.59 (1.73), respectively. In subjects satisfying criterion B, the area under the receiver operating characteristic curve was 0.951 (95% confidence interval, 0.931-0.971). The CCI discrimination values of 1.52 or 1.63 showed 90.3% sensitivity and 90% specificity, or 71.5% sensitivity and 95% specificity, respectively, for discriminating acquired colour vision impairment (ACVI).ConclusionWe provided the 90th and 95th percentiles in a young to middle-aged healthy population. The CCI is in good agreement with the diagnosis of ACVI. Our results could be helpful for using D-15DS for screening purposes.
KW - Colour confusion index
KW - Colour discrimination function
KW - Discrimination value
KW - Farnsworth-Munsell 100-hue test
KW - Lanthony desaturated D-15 pane test
KW - Reference interval
UR - http://www.scopus.com/inward/record.url?scp=67650678405&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67650678405&partnerID=8YFLogxK
U2 - 10.1038/eye.2008.292
DO - 10.1038/eye.2008.292
M3 - Article
C2 - 18836418
AN - SCOPUS:67650678405
SN - 0950-222X
VL - 23
SP - 1329
EP - 1335
JO - Eye
JF - Eye
IS - 6
ER -