TY - JOUR
T1 - Robotic assessment of upper limb function after proximal humeral fracture
T2 - Personal experience as a patient and occupational therapist
AU - Nishimoto, Atsuko
AU - Otaka, Yohei
AU - Kasuga, Shoko
AU - Otaka, Eri
AU - Yamazaki, Kotaro
AU - Ushiba, Junichi
AU - Liu, Meigen
N1 - Publisher Copyright:
© 2016 by The Keio Journal of Medicine.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016
Y1 - 2016
N2 - Robotics is an emerging field in rehabilitation medicine. Robots have the potential to complement traditional clinical assessments because they can measure functions more precisely and quantitatively than current clinical assessments. We present a patient with a proximal humeral fracture whose recovery process was evaluated with an exoskeleton robotic device. The patient, a 34-year-old woman, suffered a left proximal humeral fracture while snowboarding. She is an occupational therapist and is the first author of this study. With conservative therapy, fracture union was seen on X-ray at 6 weeks post-injury. At that time, the patient was permitted to move her left upper limb actively within the tolerance of pain. We assessed the function of the injured upper limb at 6, 7, and 12 weeks post-injury with the KINARM exoskeleton robotic device and with conventional clinical measures. The active range of motion and the muscle strength of the left shoulder improved over time. Using robotic assessment, the precise movement profiles, position sense, and functional ability of both arms were quantified and also showed progressive improvement over time. Assessment with a robotic device of the recovery process after proximal humeral fracture allowed quantification of functional impairments that could not be felt subjectively nor identified with conventional clinical assessments.
AB - Robotics is an emerging field in rehabilitation medicine. Robots have the potential to complement traditional clinical assessments because they can measure functions more precisely and quantitatively than current clinical assessments. We present a patient with a proximal humeral fracture whose recovery process was evaluated with an exoskeleton robotic device. The patient, a 34-year-old woman, suffered a left proximal humeral fracture while snowboarding. She is an occupational therapist and is the first author of this study. With conservative therapy, fracture union was seen on X-ray at 6 weeks post-injury. At that time, the patient was permitted to move her left upper limb actively within the tolerance of pain. We assessed the function of the injured upper limb at 6, 7, and 12 weeks post-injury with the KINARM exoskeleton robotic device and with conventional clinical measures. The active range of motion and the muscle strength of the left shoulder improved over time. Using robotic assessment, the precise movement profiles, position sense, and functional ability of both arms were quantified and also showed progressive improvement over time. Assessment with a robotic device of the recovery process after proximal humeral fracture allowed quantification of functional impairments that could not be felt subjectively nor identified with conventional clinical assessments.
KW - Motor skills
KW - Quantitative evaluation
KW - Robotics
KW - Upper extremity
UR - http://www.scopus.com/inward/record.url?scp=84989181305&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84989181305&partnerID=8YFLogxK
U2 - 10.2302/kjm.2015-0006-CR
DO - 10.2302/kjm.2015-0006-CR
M3 - Article
C2 - 27665866
AN - SCOPUS:84989181305
SN - 0022-9717
VL - 65
SP - 57
EP - 63
JO - Keio Journal of Medicine
JF - Keio Journal of Medicine
IS - 3
ER -