Seismic risk assessment of building-elevator system with non-proportional damping using complex complete quadratic combination method

Tetsuya Kita, Masayuki Kohiyama

Research output: Contribution to journalArticlepeer-review

Abstract

An elevator set up in a high-rise building may cause a problem of elevator rope sway. To solve this problem, the responses of buildingelevator systems are examined based on the Complex Complete Quadratic Combination method and damage risk is evaluated with respect to possible earthquakes in Chuetsu district of Niigata Prefecture and the northwestern part of Chiba Prefecture. It is observed that some positions of elevator car can reduce the damage risk of main rope by shifting the natural periods of the rope away from the natural periods of the building.

Original languageEnglish
Pages (from-to)883-888
Number of pages6
JournalAIJ Journal of Technology and Design
Volume16
Issue number34
DOIs
Publication statusPublished - 2010 Oct

Keywords

  • Complex Complete Quadratic Combination method
  • Earthquake response analysis
  • Elevator
  • Main rope
  • Probabilistic safety assessment

ASJC Scopus subject areas

  • Architecture
  • Building and Construction

Fingerprint

Dive into the research topics of 'Seismic risk assessment of building-elevator system with non-proportional damping using complex complete quadratic combination method'. Together they form a unique fingerprint.