T1 - Study on a new index of fetal respiratory function
T2 - a novel optical analysis of the amniotic fluid by the vacuum-dried infrared attenuated total reflection (ATR) method.
AU - Kobayashi, H.
AU - Kobayashi, M.
AU - Arai, T.
AU - Kikuchi, M.
AU - Okino, H.
PY - 1990/11
Y1 - 1990/11
N2 - For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called "PA1740") were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.
AB - For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called "PA1740") were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.
UR - http://www.scopus.com/inward/record.url?scp=0025519104&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025519104&partnerID=8YFLogxK
M3 - Article
C2 - 2131649
AN - SCOPUS:0025519104
SN - 0385-0005
VL - 15
SP - 425
EP - 433
JO - The Tokai journal of experimental and clinical medicine
JF - The Tokai journal of experimental and clinical medicine
IS - 6
ER -