TY - JOUR
T1 - System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction
AU - Uchiyama, Takanori
AU - Sakai, Hiroaki
N1 - Funding Information:
Acknowledgments This work was supported by JSPS KAKENHI Grant Number 24560530.
PY - 2013/12
Y1 - 2013/12
N2 - The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The MMGs were detected with either a capacitor microphone or an acceleration sensor. The transfer functions between stimulation and the MMG and between stimulation and torque were identified by the singular value decomposition method. The torque and the MMG, which were detected with a capacitor microphone, DMMG, were approximated with a second- and a third-order model, respectively. The natural frequency of the torque, reflecting longitudinal mechanical characteristics, did not show a significant difference from that of the DMMG. The MMG detected with an acceleration sensor was approximated with a fourth-order model. The natural frequencies of the AMMG reflecting the muscle and subcutaneous tissue in the transverse direction were obtained. Both DMMG and AMMG have to be measured to investigate the model of the MMG system for parallel-fibered muscle. The MMG system of parallel-fibered muscle was also modeled with a sixth-order model.
AB - The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The MMGs were detected with either a capacitor microphone or an acceleration sensor. The transfer functions between stimulation and the MMG and between stimulation and torque were identified by the singular value decomposition method. The torque and the MMG, which were detected with a capacitor microphone, DMMG, were approximated with a second- and a third-order model, respectively. The natural frequency of the torque, reflecting longitudinal mechanical characteristics, did not show a significant difference from that of the DMMG. The MMG detected with an acceleration sensor was approximated with a fourth-order model. The natural frequencies of the AMMG reflecting the muscle and subcutaneous tissue in the transverse direction were obtained. Both DMMG and AMMG have to be measured to investigate the model of the MMG system for parallel-fibered muscle. The MMG system of parallel-fibered muscle was also modeled with a sixth-order model.
KW - Abductor pollicis brevis muscle
KW - Acceleration
KW - Displacement
KW - Mechanomyogram
KW - System identification
UR - http://www.scopus.com/inward/record.url?scp=84896690595&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84896690595&partnerID=8YFLogxK
U2 - 10.1007/s11517-013-1107-9
DO - 10.1007/s11517-013-1107-9
M3 - Article
C2 - 23934080
AN - SCOPUS:84896690595
SN - 0140-0118
VL - 51
SP - 1349
EP - 1355
JO - Medical and Biological Engineering and Computing
JF - Medical and Biological Engineering and Computing
IS - 12
ER -