TY - JOUR
T1 - Tactile estimation of molded plastic plates based on the estimated impulse responses of mechanoreceptive units
AU - Nobuyama, Lisako
AU - Kurashina, Yuta
AU - Kawauchi, Kei
AU - Matsui, Koji
AU - Takemura, Kenjiro
N1 - Funding Information:
Funding: This work was supported in part by the Keio Gijuku Fukuzawa Memorial Fund for the Advancement of Education and Research.
Publisher Copyright:
© 2018 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2018/5/16
Y1 - 2018/5/16
N2 - This study proposes a tactile estimation method of molded plastic plates based on human tactile perception characteristics. Plastic plates are often used in consumer products. The tactile evaluation plays an important role in product development. However, physical quantities not taking into account human tactile perception have been employed in previous tactile estimation procedures. Hence, in this study, we adopted the vibrational thresholds of the mechanoreceptive units—FA I, FA II, SA I and SA II—for stimuli detection and developed a tactile estimation method for plastic plates that clarified the mechanoreceptive units related to tactile sensation. The developed tactile sensor consists of a base and a silicone rubber pad that contains strain gauges in it. We detected vibration during touch by the sensor and calculated the estimation of the firing values of the cutaneous mechanoreceptors, which are the essential data obtained by humans during tactile perception, in comparison to the amplitude spectrum of the vibration with the threshold amplitude of each mechanoreceptive unit. Simultaneously, we calculated the relationship between the normal and tangential forces recorded while the sensor ran over the samples. As a result of stepwise linear regression analysis using these values as explanatory variables, the evaluation scores for Soft were successfully estimated using the firing value of FA II and the relationship between normal/tangential forces, and the evaluation scores for Rough were estimated using the SA I firing value.
AB - This study proposes a tactile estimation method of molded plastic plates based on human tactile perception characteristics. Plastic plates are often used in consumer products. The tactile evaluation plays an important role in product development. However, physical quantities not taking into account human tactile perception have been employed in previous tactile estimation procedures. Hence, in this study, we adopted the vibrational thresholds of the mechanoreceptive units—FA I, FA II, SA I and SA II—for stimuli detection and developed a tactile estimation method for plastic plates that clarified the mechanoreceptive units related to tactile sensation. The developed tactile sensor consists of a base and a silicone rubber pad that contains strain gauges in it. We detected vibration during touch by the sensor and calculated the estimation of the firing values of the cutaneous mechanoreceptors, which are the essential data obtained by humans during tactile perception, in comparison to the amplitude spectrum of the vibration with the threshold amplitude of each mechanoreceptive unit. Simultaneously, we calculated the relationship between the normal and tangential forces recorded while the sensor ran over the samples. As a result of stepwise linear regression analysis using these values as explanatory variables, the evaluation scores for Soft were successfully estimated using the firing value of FA II and the relationship between normal/tangential forces, and the evaluation scores for Rough were estimated using the SA I firing value.
KW - Human tactile perception
KW - Mechanoreceptive units
KW - Sensory evaluation
KW - Tactile sensor
UR - http://www.scopus.com/inward/record.url?scp=85047126020&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85047126020&partnerID=8YFLogxK
U2 - 10.3390/s18051588
DO - 10.3390/s18051588
M3 - Article
C2 - 29772740
AN - SCOPUS:85047126020
SN - 1424-8220
VL - 18
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 5
M1 - 1588
ER -