T1 - Theory and practice of rapid flow-through analysis based on ion-selective optode detection and its application to sodium ion determination
AU - Hisamoto, Hideaki
AU - Satoh, Sayaka
AU - Satoh, Kazunari
AU - Tsubuku, Michiko
AU - Siswanta, Dwi
AU - Shichi, Yushi
AU - Koike, Yasuhiro
AU - Suzuki, Koji
N1 - Copyright:
Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.
PY - 1999/9/20
Y1 - 1999/9/20
N2 - One simple example of a rapid flow-through analysis (RFA) system based on ion-selective optode detection was demonstrated, and its performance was discussed. The RFA is a flow analytical method based on a reagentless analyte flow injection system combined with an analyte selective monitor/sensor such as an optical chemical sensor (optode) involving mathematical response simulation using a semi-empirical theoretical response equation. The response of RFA with optode detection can basically be expressed by the equation derived from Fick's law of diffusion and Kubelka-Munk's law, and two other variable parameters in relation to the experimental response. Mathematically simulated results using the proposed equation indicated that the equation can be useful for the prediction of the flow analytical response. In the present demonstration of RFA, highly selective ionophores based on 16-crown-5 derivatives were used for the ion-sensing component of the optode for sodium ion determination. A sodium ion-selective optode based on C14-DD16C5 and KD-A3 exhibited high selectivity for sodium ion over potassium ion, with a selectivity coefficient (logK(i,j)(opt)) of -2.6. This optode responded to sodium ion in the concentration range from 10-5 to 10-1M at pH 8.0 by measuring the absorbance change at 510nm in the sensing phase of the optode. The RFA system equipped with a sodium ion-selective optode offers a reagent-less advanced ion-determination methodology for conventional flow injection analysis. Copyright (C) 1999 Elsevier Science B.V.
AB - One simple example of a rapid flow-through analysis (RFA) system based on ion-selective optode detection was demonstrated, and its performance was discussed. The RFA is a flow analytical method based on a reagentless analyte flow injection system combined with an analyte selective monitor/sensor such as an optical chemical sensor (optode) involving mathematical response simulation using a semi-empirical theoretical response equation. The response of RFA with optode detection can basically be expressed by the equation derived from Fick's law of diffusion and Kubelka-Munk's law, and two other variable parameters in relation to the experimental response. Mathematically simulated results using the proposed equation indicated that the equation can be useful for the prediction of the flow analytical response. In the present demonstration of RFA, highly selective ionophores based on 16-crown-5 derivatives were used for the ion-sensing component of the optode for sodium ion determination. A sodium ion-selective optode based on C14-DD16C5 and KD-A3 exhibited high selectivity for sodium ion over potassium ion, with a selectivity coefficient (logK(i,j)(opt)) of -2.6. This optode responded to sodium ion in the concentration range from 10-5 to 10-1M at pH 8.0 by measuring the absorbance change at 510nm in the sensing phase of the optode. The RFA system equipped with a sodium ion-selective optode offers a reagent-less advanced ion-determination methodology for conventional flow injection analysis. Copyright (C) 1999 Elsevier Science B.V.
KW - Chemical sensor
KW - Flow-analysis
KW - Ion sensor
KW - Ion-selective optode
KW - Ionophore
UR - http://www.scopus.com/inward/record.url?scp=0032833930&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032833930&partnerID=8YFLogxK
U2 - 10.1016/S0003-2670(99)00482-1
DO - 10.1016/S0003-2670(99)00482-1
M3 - Article
AN - SCOPUS:0032833930
SN - 0003-2670
VL - 396
SP - 131
EP - 141
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
IS - 2-3
ER -