TY - JOUR
T1 - Three-dimensional computer-generated head model reconstructed from cephalograms, facial photographs, and dental cast models
AU - Nakasima, Akihiko
AU - Terajima, Masahiko
AU - Mori, Noriko
AU - Hoshino, Yoshihiro
AU - Tokumori, Kenji
AU - Aoki, Yoshimitu
AU - Hashimoto, Shuji
PY - 2005/3
Y1 - 2005/3
N2 - Purpose: Three-dimensional (3D) computer models of the human craniofacial structure have been constructed with computed tomography (CT). However, the high cost of CT and the radiation exposure are drawbacks to this method. Attempts to create a 3D reconstruction from lateral and frontal cephalograms have failed because of problems with magnification, distortion, and limitations of landmark identification, among others. We introduce a new method that creates a standard head model for a patient from anatomic measurement points extracted from x-ray images, facial stereo photographs, and dental casts. Material: To obtain precise 3D coordinates from cephalograms, several equations were introduced to compensate for radiographic image magnification and distortion. Results: By comparing the constructed model and 3D-CT images, this method proved to be accurate. Conclusions: It is possible to produce a 3D head model on a personal computer and to view it from any desired angle; this will provide easy-to-understand information for patients and establish a diagnostic or therapeutic method for communication with other health care providers.
AB - Purpose: Three-dimensional (3D) computer models of the human craniofacial structure have been constructed with computed tomography (CT). However, the high cost of CT and the radiation exposure are drawbacks to this method. Attempts to create a 3D reconstruction from lateral and frontal cephalograms have failed because of problems with magnification, distortion, and limitations of landmark identification, among others. We introduce a new method that creates a standard head model for a patient from anatomic measurement points extracted from x-ray images, facial stereo photographs, and dental casts. Material: To obtain precise 3D coordinates from cephalograms, several equations were introduced to compensate for radiographic image magnification and distortion. Results: By comparing the constructed model and 3D-CT images, this method proved to be accurate. Conclusions: It is possible to produce a 3D head model on a personal computer and to view it from any desired angle; this will provide easy-to-understand information for patients and establish a diagnostic or therapeutic method for communication with other health care providers.
UR - http://www.scopus.com/inward/record.url?scp=15244343122&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=15244343122&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2003.11.030
DO - 10.1016/j.ajodo.2003.11.030
M3 - Article
C2 - 15775942
AN - SCOPUS:15244343122
SN - 0889-5406
VL - 127
SP - 282
EP - 292
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
IS - 3
ER -