TY - GEN
T1 - 1μm-thickness 64-channel surface electromyogram measurement sheet with 2V organic transistors for prosthetic hand control
AU - Fuketa, Hiroshi
AU - Yoshioka, Kazuaki
AU - Shinozuka, Yasuhiro
AU - Ishida, Koichi
AU - Yokota, Tomoyuki
AU - Matsuhisa, Naoji
AU - Inoue, Yusuke
AU - Sekino, Masaki
AU - Sekitani, Tsuyoshi
AU - Takamiya, Makoto
AU - Someya, Takao
AU - Sakurai, Takayasu
PY - 2013
Y1 - 2013
N2 - A surface electromyogram (EMG), which measures a voltage waveform produced by skeletal muscles on skin, is an important tool for applications detecting the human will of motion, such as for prosthetic hands and prosthetic legs. In the application to a prosthetic hand, a multipoint EMG measurement is required to precisely control the hand [1, 2]. Conventional multipoint measurements with a passive electrode array [1-3], however, have two problems: 1) Measurement over a long time period is annoying, because the EMG electrodes placed on the skin are rigid, and 2) the signal integrity of EMG is degraded, because the number of wires between the electrodes and the front-end circuits increases with increasing number of measurement points. To address these challenges, a surface EMG measurement sheet (SEMS) on which an EMG electrode array and a front-end amplifier array with 2V organic transistors are integrated on a 1μm-thick ultra-flexible film is developed to control prosthetic hands. The developed SEMS enables a comfortable long-time measurement without signal integrity degradation.
AB - A surface electromyogram (EMG), which measures a voltage waveform produced by skeletal muscles on skin, is an important tool for applications detecting the human will of motion, such as for prosthetic hands and prosthetic legs. In the application to a prosthetic hand, a multipoint EMG measurement is required to precisely control the hand [1, 2]. Conventional multipoint measurements with a passive electrode array [1-3], however, have two problems: 1) Measurement over a long time period is annoying, because the EMG electrodes placed on the skin are rigid, and 2) the signal integrity of EMG is degraded, because the number of wires between the electrodes and the front-end circuits increases with increasing number of measurement points. To address these challenges, a surface EMG measurement sheet (SEMS) on which an EMG electrode array and a front-end amplifier array with 2V organic transistors are integrated on a 1μm-thick ultra-flexible film is developed to control prosthetic hands. The developed SEMS enables a comfortable long-time measurement without signal integrity degradation.
UR - http://www.scopus.com/inward/record.url?scp=84876576453&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84876576453&partnerID=8YFLogxK
U2 - 10.1109/ISSCC.2013.6487656
DO - 10.1109/ISSCC.2013.6487656
M3 - Conference contribution
AN - SCOPUS:84876576453
SN - 9781467345132
T3 - Digest of Technical Papers - IEEE International Solid-State Circuits Conference
SP - 104
EP - 105
BT - 2013 IEEE International Solid-State Circuits Conference, ISSCC 2013 - Digest of Technical Papers
T2 - 2013 60th IEEE International Solid-State Circuits Conference, ISSCC 2013
Y2 - 17 February 2013 through 21 February 2013
ER -