抄録
Purpose: To modify a surgical catheterization method using the bent needle introducer in small animals. Methods: Eight-week-old male Lewis rats were used in the study. A needle introducer was created by bending a 21G injection needle at 45°. The bent needle introducer was used for catheter insertion into the left femoral artery of the rats under anesthesia. As a control, a catheter was directly inserted into the blood vessel without the introducer. The insertion time of each method was measured. Blood pressure and heart rate were measured 24 h after catheter insertion using the telemetry system. Results: Using the introducer, the catheter was successfully inserted within a short time in all rats. Without the introducer, a longer duration was required for catheter insertion. The frequency of the insertion with no catheter-based errors with the introducer tended to be higher than that without the introducer. The mean arterial pressure and heart rate 24 h after catheter insertion in each group were almost the same. Conclusions: We developed a surgical catheterization method using the introducer in small animals. This could potentially reduce the frequency of the insertion with catheter-based errors and insertion time.
本文言語 | English |
---|---|
論文番号 | e202001004 |
ページ(範囲) | 1-8 |
ページ数 | 8 |
ジャーナル | Acta Cirurgica Brasileira |
巻 | 35 |
号 | 10 |
DOI | |
出版ステータス | Published - 2020 |
ASJC Scopus subject areas
- 外科