A new hydrodynamic oscillator type flowmeter.

S. Honda, H. Yamasaki

研究成果: Chapter

2 被引用数 (Scopus)

抄録

Both vortex flowmeters and fluidic flowmeters form a family of the hydrodynamic oscillator type which have geometrical and hydrodynamic complementarity. The objectives of this study were to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so called target, which was derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter. (A)

本文言語English
ホスト出版物のタイトルIN
ホスト出版物のサブタイトルFLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.)
出版社Pergamon Press
2 , Oxford, U.K., Pergamon Press, 1986, p.623-628. (ISBN 0-08-031681-6)
ISBN(印刷版)0080316816, 9780080316819
出版ステータスPublished - 1986 1月 1