TY - JOUR
T1 - A Serial Observation of Coronary Thrombi in Vivo by a New Percutaneous Transluminal Coronary Angioscope
AU - Mizuno, Kyoichi
AU - Miyamoto, Akira
AU - Isojima, Kazushige
AU - Kurita, Akira
AU - Nakamura, Haruo
AU - Senoo, Akira
AU - Arai, Tsunenori
AU - Kikuchi, Makoto
PY - 1992/2
Y1 - 1992/2
N2 - This study was undertaken to observe coronary thrombus formation serially from an antegrade perspective by means of a new thin flexible angioscope that has an inflatable balloon at the distal tip and an angulation mechanism. To test its capabilities, thrombi were induced in the left anterior descending coronary artery of 11 dogs by copper coils, and the thrombi were then observed through this angioscope, which had been introduced into the coronary artery by a guide catheter. Five minutes after insertion of the copper coil, fibrin-like material and white components of the thrombi were seen massing around the copper coil. Then, thin, mixed thrombotic white and red components formed around the copper coil. At fifteen minutes after the copper coil insertion, the thrombi grew in size. Ten minutes later, the thrombi finally obstructed the coro nary lumen in most dogs. The red and white appearance of these thrombi was confirmed macroscopi cally, and the microscopic findings of these occluding thrombi revealed a fibrinous network with platelet aggregates and blood cell coagulation. Though ordinary angiography cannot reveal the precise features of the various coronary thrombi, this new angioscope was able to discern them from the antegrade perspective. The capabilities of this angioscope, which enabled these findings, should prove helpful in evaluating the stages of human coronary thrombosis. Of additional benefit, this angioscope can be used clinically for cardiac catheterization.
AB - This study was undertaken to observe coronary thrombus formation serially from an antegrade perspective by means of a new thin flexible angioscope that has an inflatable balloon at the distal tip and an angulation mechanism. To test its capabilities, thrombi were induced in the left anterior descending coronary artery of 11 dogs by copper coils, and the thrombi were then observed through this angioscope, which had been introduced into the coronary artery by a guide catheter. Five minutes after insertion of the copper coil, fibrin-like material and white components of the thrombi were seen massing around the copper coil. Then, thin, mixed thrombotic white and red components formed around the copper coil. At fifteen minutes after the copper coil insertion, the thrombi grew in size. Ten minutes later, the thrombi finally obstructed the coro nary lumen in most dogs. The red and white appearance of these thrombi was confirmed macroscopi cally, and the microscopic findings of these occluding thrombi revealed a fibrinous network with platelet aggregates and blood cell coagulation. Though ordinary angiography cannot reveal the precise features of the various coronary thrombi, this new angioscope was able to discern them from the antegrade perspective. The capabilities of this angioscope, which enabled these findings, should prove helpful in evaluating the stages of human coronary thrombosis. Of additional benefit, this angioscope can be used clinically for cardiac catheterization.
UR - http://www.scopus.com/inward/record.url?scp=0026538409&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026538409&partnerID=8YFLogxK
U2 - 10.1177/000331979204300202
DO - 10.1177/000331979204300202
M3 - Article
C2 - 1536480
AN - SCOPUS:0026538409
SN - 0003-3197
VL - 43
SP - 91
EP - 99
JO - Angiology
JF - Angiology
IS - 2
ER -