Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes

研究成果: Article査読

抄録

This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated using nine formulas: Barrett True-K, Barrett True-K TK, Haigis-L, Haigis TK, Pearl-DGS, Hoffer QST, Hoffer QST PK, EVO K, and EVO PK. Statistical comparisons utilized Friedman test, Conover’s all-pairs post-hoc, Cochran’s Q, and McNemar post-hoc testing. Root-Mean-Square Error (RMSE) was compared with heteroscedastic testing. Barrett True-K TK had the lowest median predicted refractive error (-0.01). EVO PK had the smallest median absolute error (0.20). EVO PK had the highest percentage of eyes within ± 0.25 D of the predicted value (58.9%), significantly better than Haigis-L (p = 0.047). EVO PK had the lowest mean RMSE value (0.499). The EVO PK formula yielded the most accurate IOL power calculation in post-myopic LASIK eyes, with TK/PK values enhancing accuracy.

本文言語English
論文番号26560
ジャーナルScientific reports
14
1
DOI
出版ステータスPublished - 2024 12月