TY - JOUR
T1 - Accurate natural frequency estimation method for myotonometer using a system identification method
AU - Uchiyama, Takanori
AU - Ogura, Yuri
N1 - Publisher Copyright:
© 2020, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
PY - 2020
Y1 - 2020
N2 - The purpose of this study is to propose a novel method to estimate natural frequency using a myotonometer with the aid of a system identification technique. A myotonometer is an instrument that measures muscle hardness based on an indentation method. We utilized a MyotonPRO (Myoton AS, Tallinn, Estonia) as a myotonometer. The myotonometer applies a mechanical rectangular pulse to an object and records the acceleration of the indenter. The built-in program of the myotonometer calculates the natural frequency of the object from the recorded acceleration with fast Fourier transformation. This calculation, however, showed the dependency of the natural frequency on the rectangular pulse width. To overcome the dependency, we propose a novel technique to estimate the natural frequency. Our proposed method extracted the acceleration that was not affected by the rectangular mechanical pulse. Then the extracted acceleration was regarded as an output of a system from the mechanical pulse to the acceleration. The transfer function of the system was identified, and then the natural frequency of the transfer function was calculated. We applied the proposed method to the estimation of the natural frequency of a gel-like object mimicking human soft tissue. The proposed method provided a smaller standard deviation of the natural frequency than the built-in program of the myotonometer.
AB - The purpose of this study is to propose a novel method to estimate natural frequency using a myotonometer with the aid of a system identification technique. A myotonometer is an instrument that measures muscle hardness based on an indentation method. We utilized a MyotonPRO (Myoton AS, Tallinn, Estonia) as a myotonometer. The myotonometer applies a mechanical rectangular pulse to an object and records the acceleration of the indenter. The built-in program of the myotonometer calculates the natural frequency of the object from the recorded acceleration with fast Fourier transformation. This calculation, however, showed the dependency of the natural frequency on the rectangular pulse width. To overcome the dependency, we propose a novel technique to estimate the natural frequency. Our proposed method extracted the acceleration that was not affected by the rectangular mechanical pulse. Then the extracted acceleration was regarded as an output of a system from the mechanical pulse to the acceleration. The transfer function of the system was identified, and then the natural frequency of the transfer function was calculated. We applied the proposed method to the estimation of the natural frequency of a gel-like object mimicking human soft tissue. The proposed method provided a smaller standard deviation of the natural frequency than the built-in program of the myotonometer.
KW - Myotonometer
KW - Natural frequency
KW - System identification
UR - http://www.scopus.com/inward/record.url?scp=85114505005&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85114505005&partnerID=8YFLogxK
U2 - 10.11239/JSMBE.ANNUAL58.598
DO - 10.11239/JSMBE.ANNUAL58.598
M3 - Article
AN - SCOPUS:85114505005
SN - 1881-4379
VL - 58
SP - 598
EP - 599
JO - Transactions of Japanese Society for Medical and Biological Engineering
JF - Transactions of Japanese Society for Medical and Biological Engineering
IS - Proc
ER -