In this paper, conservatisms of current plugging criteria on steam generator tubes are reviewed and six new failure prediction models for dual through-wall cracks are proposed. In order to determine the optimum ones among these local or global failure prediction models, a series of plastic collapse tests and corresponding finite element analyses are carried out with respect to two adjacent axial through-wall cracks in thin plates. Then, reaction force model, plastic zone contact model and COD (Crack Opening Displacement) base model were selected as the optimum ones for integrity assessment of steam generator tubes with dual cracks.