Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography

Tsuyoshi Isogai, Masahiro Jinzaki, Yutaka Tanami, Hiroyuki Kusuzaki, Minoru Yamada, Sachio Kuribayashi

研究成果: Article査読

20 被引用数 (Scopus)

抄録

Purpose: The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. Materials and methods: A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg-1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg-1 with 350 mg I/ml; protocol C, total of 0.7 ml kg-1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 HU was compared on a pervessel and per-patient basis. Results: The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P < 0.05). The attenuation value also signifi cantly exceeded 325 HU with protocol C (95% and 90%, respectively) more often than with protocol A or B on the per-patient analysis (P < 0.05). Conclusion: A total of at least 0.7 ml kg-1 contrast material with 350 mg/ml iodine concentration is required to achieve optimal coronary CT attenuation (>325 HU) with 64-detector CT when using an injection duration of 10 s.

本文言語English
ページ(範囲)33-38
ページ数6
ジャーナルJapanese Journal of Radiology
29
1
DOI
出版ステータスPublished - 2011 1月

ASJC Scopus subject areas

  • 放射線学、核医学およびイメージング

フィンガープリント

「Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル