Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions

Yoshikane Yamauchi, Yotaro Izumi, Seishi Nakatsuka, Masanori Inoue, Yuichiro Hayashi, Makio Mukai, Hiroaki Nomori

研究成果: Article査読

46 被引用数 (Scopus)

抄録

Objective: The diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity (GGO) pulmonary lesions was evaluated. Materials and methods: Out of 90 patients who underwent CT fluoroscopy-guided core needle biopsy of GGO lesions at our institution, the biopsy results and the final diagnoses were retrospectively compared in 67 patients with available data (one lesion per patient). Diagnostic performance was also compared according to the lesion size (≤10 mm (n = 8) versus 11-20 mm (n = 42) versus >20 mm (n = 17)), the percentage of GGO component (50-90% (n = 31) versus >90% (n = 36)), and the length of needle path (≤7 cm (n = 45) versus >7 cm (n = 22)). Finally, all 90 cases were reviewed for complications. Results: The overall sensitivity, specificity, and accuracy were 97%, 100%, and 97%, respectively. The diagnostic sensitivity and accuracy tended to be lower in smaller lesions (≤10 mm; 86 and 88%, 11-20 mm; 97 and 98%, >20 mm; 100 and 100%, respectively, p > 0.05), and in lesions with lower percentage of GGO component (50-90%; 93 and 94%, >90%; 100 and 100%, respectively, p = 0.21), but statistical significances were not reached. The sensitivity and accuracy were not significantly affected by the length of needle path (≤7 cm; 98 and 98%, >7 cm; 95 and 96%, respectively, p = 1.00). Fourteen patients (16%) developed pneumothoraces, and 13 patients (14%) experienced mild hemoptysis, all of which resolved conservatively. Conclusion: The diagnostic performance was satisfactory, and it was considered that the procedure was appropriate for GGO lesions regardless of lesion size, the percentage of GGO component, or the length of needle path. The procedure was also feasible without any major complications.

本文言語English
ページ(範囲)e85-e89
ジャーナルEuropean Journal of Radiology
79
2
DOI
出版ステータスPublished - 2011 8月

ASJC Scopus subject areas

  • 放射線学、核医学およびイメージング

フィンガープリント

「Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル