メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Difference in the accuracy of the third-generation algorithm and the first-generation algorithm of FreeStyle Libre continuouglucose monitoring device

  • Takashi Murata
  • , Naoki Sakane
  • , Yushi Hirota
  • , Masao Toyoda
  • , Munehide Matsuhisa
  • , Akio Kuroda
  • , Arata Itoh
  • , Shu Meguro
  • , Junnosuke Miura
  • , Yuka Matoba
  • , Ken Kato
  • , Shota Suzuki
  • , Akira Shimada

研究成果: Article › 査読

抄録

Background: FreeStyle Libre uses the algorithm to calculate the sensor glucose (SG) levels. The manufacturer announced that they had changed the algorithm from the first generation (Gen. 1) to the third generation (Gen. 3). To assess the difference, we conducted an observational study to analyze the characteristics of the measurements by these two algorithms compared to the capillary blood glucose (BG) levels. Methods: Participants with type 1 diabetes wore two FreeStyle Libre sensors, one on the left arm used with Gen. 3 algorithm, and another on the right arm used in combination with the FreeStyle Libre Reader with Gen. 1 algorithm. Results: Data were collected from 11 participants. The Bland-Altman analysis of the measurements by Gen. 3 algorithm showed bias of 7.4 mg / dl and no proportional bias was observed (r = 0.130). In contrast, the Bland-Altman analysis of the measurements by Gen. 1 algorithm showed bias of 4.4 mg / dl and proportional bias was observed (r = 0.424). The MARD of Gen. 3 algorithm and Gen. 1 algorithm was 11.9 ± 9.0% and 9.7 ± 8.3%, respectively (P = 0.053). Conclusion: No proportional bias in the measurements by Gen. 3 algorithm was observed, but in those by Gen. 1 algorithm. J. Med. Invest. 71: 225-231, August, 2024.

本文言語English
ページ(範囲)225-231
ページ数7
ジャーナルJournal of Medical Investigation
巻71
号3-4
DOI
出版ステータスPublished - 2024

UN SDG

この成果は、次の持続可能な開発目標に貢献しています

  1. SDG 3 - すべての人に健康と福祉を
    SDG 3 すべての人に健康と福祉を

ASJC Scopus subject areas

  • 医学一般
  • 生化学、遺伝学、分子生物学一般

フィンガープリント

「Difference in the accuracy of the third-generation algorithm and the first-generation algorithm of FreeStyle Libre continuouglucose monitoring device」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル