N2 - Active flow control, which can adapt to variable cross flow direction, is an effective technique to achieve drag reduction. The present study has investigated the effect of flap actuators to the blunt body and established a drag reduction control system for variation of cross flow direction. Numerical simulations were performed in order to obtain the optimal flap positions for drag reduction. A three force components transducer was introduced to measure drag force in order to investigate optimal flap angle to the flow direction. And flow structure around the body was examined using PIV (Particle Image Velocimetry). In this drag reduction system, flap actuators were controlled to the optical angle by detection of flow direction by investigation of non-separating flow, using pressure transducers as sensors. The flap actuators at the leading edge of the body promoted separated shear layer to approach to the body and lead to drag reduction at the optimal flap angle. Drag reduction rate is up to about 30%. This drag reduction control system adapted to variable cross flow direction raging from 0 to 40 deg. and reacted for drag reduction in 0.1 s.
AB - Active flow control, which can adapt to variable cross flow direction, is an effective technique to achieve drag reduction. The present study has investigated the effect of flap actuators to the blunt body and established a drag reduction control system for variation of cross flow direction. Numerical simulations were performed in order to obtain the optimal flap positions for drag reduction. A three force components transducer was introduced to measure drag force in order to investigate optimal flap angle to the flow direction. And flow structure around the body was examined using PIV (Particle Image Velocimetry). In this drag reduction system, flap actuators were controlled to the optical angle by detection of flow direction by investigation of non-separating flow, using pressure transducers as sensors. The flap actuators at the leading edge of the body promoted separated shear layer to approach to the body and lead to drag reduction at the optimal flap angle. Drag reduction rate is up to about 30%. This drag reduction control system adapted to variable cross flow direction raging from 0 to 40 deg. and reacted for drag reduction in 0.1 s.
KW - Boundary layer
KW - Flow control
KW - Flow drag
KW - Particle image velocimetry
KW - Pressure distribution
UR - http://www.scopus.com/inward/record.url?scp=79751480121&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79751480121&partnerID=8YFLogxK
U2 - 10.1299/kikaib.76.771_1742
DO - 10.1299/kikaib.76.771_1742
M3 - Article
AN - SCOPUS:79751480121
SN - 0387-5016
VL - 76
SP - 1742
EP - 1749
JO - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
JF - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
IS - 771
ER -