抄録
Electromagnetic flowmeters, which have been one of the standard instrument to measure liquid flowrate in industry, are applied to tomographic imaging of flow velocity field. It is possible to evaluate velocity profiles through the proper design of the magnetic field. In this paper, we propose a new design of the 3-D field excitation with two sets of eight magnetic poles and of eight signal pick-up electrodes. From the simulation study under a laminar swirling flow, it is clarified that the reconstruction of 3-D velocity distribution can be achieved.
| 本文言語 | English |
|---|---|
| ページ | 1599-1605 |
| ページ数 | 7 |
| 出版ステータス | Published - 2004 12月 1 |
| イベント | SICE Annual Conference 2004 - Sapporo, Japan 継続期間: 2004 8月 4 → 2004 8月 6 |
Other
| Other | SICE Annual Conference 2004 |
|---|---|
| 国/地域 | Japan |
| City | Sapporo |
| Period | 04/8/4 → 04/8/6 |
ASJC Scopus subject areas
- 制御およびシステム工学
- コンピュータ サイエンスの応用
- 電子工学および電気工学
フィンガープリント
「Estimation of 3-D flow tomography through Electro Magnetic Induction」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS