Estimation of total oxygen transfer into aeration tank

Kazue Shibata, Koichi Terasaka, Satoko Fujioka, Kaoru Kato

研究成果: Article査読

3 被引用数 (Scopus)

抄録

A method for estimation of the volumetric mass transfer coefficient of an entire aeration tank for optimization of tank design was investigated. The gas holdup, bubble diameter, and volumetric mass transfer coefficient of an aeration tank were measured by experiments and the experimental results were compared with two estimation method. One method used empirical equations, while the other used CFD simulation. The rate of oxygen transfer into the aeration tank was assumed to be the sum of the rates at the bubble-liquid interface and free surface. The empirical equation method showed good agreement with the measured gas holdup by assuming that the aeration tank was divided two zones. On the other hand, the CFD simulation method provided a good estimation of the gas holdup and bubble diameter. The sum of the estimated volumetric mass transfer at the bubble-liquid interface and free surface showed good agreement with the measured volumetric mass transfer coefficient of the entire aeration tank.

本文言語English
ページ(範囲)588-594
ページ数7
ジャーナルJOURNAL OF CHEMICAL ENGINEERING OF JAPAN
49
7
DOI
出版ステータスPublished - 2016

ASJC Scopus subject areas

  • 化学 (全般)
  • 化学工学(全般)

フィンガープリント

「Estimation of total oxygen transfer into aeration tank」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。