TY - JOUR
T1 - Evaluation of renal function using 99mTc-MAG3 comparison with 131I-OIH by simultaneous dual energy peak acquisition method
AU - Hashimoto, T.
AU - Matsumoto, K.
AU - Ishibashi, R.
AU - Iwasaki, R.
AU - Sanmiya, T.
AU - Hashimoto, J.
AU - Kunieda, E.
AU - Nakamura, K.
AU - Kubo, A.
PY - 1995/1/1
Y1 - 1995/1/1
N2 - A newly developed 99mTc-labeled renal scintigraphic and renographic agent, 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) was studied clinically and compared with 131I-OIH in 16 patients with various renal and urinary tract disorders. The abdominal aorta and the common iliac artery were clearly visualized in the vascular phase. The renogram patterns showed the same pattern in all cases. The parameters on the renogram such as T(max), T(2/3), T( 1/2 ) were compared. The highly significant correlations of T(max), T(2/3) and T( 1/2 ) were observed between 99mTc-MAG3 and 131I-OIH with correlation coefficient of 0.982, 0.907, 0.990, respectively. In all cases, excretion of 99mTc-MAG3 was slower than that of 131I-OIH and the ratios of T(max), T(2/3) and T( 1/2 ) between 99mTc-MAG3 and 131I-OIH were 1.113 ± 0.121, 1.277 ± 0.247, 1.179 ± 0.075, respectively. It is concluded that 99mTc-MAG3 is a useful renal imaging agent as an alternative to 131I or 123I-OIH.
AB - A newly developed 99mTc-labeled renal scintigraphic and renographic agent, 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) was studied clinically and compared with 131I-OIH in 16 patients with various renal and urinary tract disorders. The abdominal aorta and the common iliac artery were clearly visualized in the vascular phase. The renogram patterns showed the same pattern in all cases. The parameters on the renogram such as T(max), T(2/3), T( 1/2 ) were compared. The highly significant correlations of T(max), T(2/3) and T( 1/2 ) were observed between 99mTc-MAG3 and 131I-OIH with correlation coefficient of 0.982, 0.907, 0.990, respectively. In all cases, excretion of 99mTc-MAG3 was slower than that of 131I-OIH and the ratios of T(max), T(2/3) and T( 1/2 ) between 99mTc-MAG3 and 131I-OIH were 1.113 ± 0.121, 1.277 ± 0.247, 1.179 ± 0.075, respectively. It is concluded that 99mTc-MAG3 is a useful renal imaging agent as an alternative to 131I or 123I-OIH.
KW - I-OIH
KW - Tc-Mag
KW - renogram
KW - simultaneous injection
UR - http://www.scopus.com/inward/record.url?scp=0028898688&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028898688&partnerID=8YFLogxK
M3 - Article
C2 - 7715099
AN - SCOPUS:0028898688
SN - 0022-7854
VL - 32
SP - 139
EP - 146
JO - Kakuigaku
JF - Kakuigaku
IS - 2