TY - JOUR
T1 - False lumen being larger than true lumen is associated with late aortic events in uncomplicated type B aortic dissection
AU - Matsushita, Akihito
AU - Tabata, Minoru
AU - Hattori, Takashi
AU - Mihara, Wahei
AU - Sato, Yasunori
N1 - Publisher Copyright:
© 2022 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.
PY - 2022/6/1
Y1 - 2022/6/1
N2 - OBJECTIVES: In uncomplicated type B aortic dissection, a large false lumen (FL) is reportedly a risk factor for late aortic events. However, it is unclear how the relationship between the false and true lumen (TL) diameters affects the dissected aorta. This study aimed to evaluate the impact on clinical outcomes of the FL being larger than the TL. METHODS: We retrospectively reviewed 111 consecutive patients with uncomplicated acute type B aortic dissection between 2004 and 2018. We divided the patients into group A (FL > TL; n = 51) and group B (FL ≤ TL; n = 60), and compared the outcomes. The endpoints were aortic events, including surgery for aortic dissection and indication for surgery, and mortality. RESULTS: The 5-year incidence rates of aortic events were 68.4% in Group A and 33.6% in Group B (P = 0.002). The 5-year all-cause mortality rates were 5.3% in Group A and 21.9% in Group B (P = 0.003). The multivariable analyses revealed that FL > TL was an independent factor associated with aortic events (adjusted hazard ratio 2.482, 95% confidence interval 1.467-4.198, P < 0.001), but had low mortality (adjusted hazard ratio 0.209, 95% confidence interval 0.073-0.597, P = 0.003). CONCLUSIONS: Patients with uncomplicated type B aortic dissection with FL > TL at admission are at increased risk of aortic events but improve mortality compared to patients with FL ≤ TL. Clinical trial registration: UMIN000036997.
AB - OBJECTIVES: In uncomplicated type B aortic dissection, a large false lumen (FL) is reportedly a risk factor for late aortic events. However, it is unclear how the relationship between the false and true lumen (TL) diameters affects the dissected aorta. This study aimed to evaluate the impact on clinical outcomes of the FL being larger than the TL. METHODS: We retrospectively reviewed 111 consecutive patients with uncomplicated acute type B aortic dissection between 2004 and 2018. We divided the patients into group A (FL > TL; n = 51) and group B (FL ≤ TL; n = 60), and compared the outcomes. The endpoints were aortic events, including surgery for aortic dissection and indication for surgery, and mortality. RESULTS: The 5-year incidence rates of aortic events were 68.4% in Group A and 33.6% in Group B (P = 0.002). The 5-year all-cause mortality rates were 5.3% in Group A and 21.9% in Group B (P = 0.003). The multivariable analyses revealed that FL > TL was an independent factor associated with aortic events (adjusted hazard ratio 2.482, 95% confidence interval 1.467-4.198, P < 0.001), but had low mortality (adjusted hazard ratio 0.209, 95% confidence interval 0.073-0.597, P = 0.003). CONCLUSIONS: Patients with uncomplicated type B aortic dissection with FL > TL at admission are at increased risk of aortic events but improve mortality compared to patients with FL ≤ TL. Clinical trial registration: UMIN000036997.
KW - Uncomplicated Stanford type B Aortic dissection
UR - http://www.scopus.com/inward/record.url?scp=85131269803&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85131269803&partnerID=8YFLogxK
U2 - 10.1093/icvts/ivac003
DO - 10.1093/icvts/ivac003
M3 - Review article
C2 - 35147677
AN - SCOPUS:85131269803
SN - 1569-9293
VL - 34
SP - 1132
EP - 1140
JO - Interactive cardiovascular and thoracic surgery
JF - Interactive cardiovascular and thoracic surgery
IS - 6
ER -