TY - JOUR
T1 - Importance of the vein of Marshall involvement in mitral isthmus ablation
AU - Fujisawa, Taishi
AU - Kimura, Takehiro
AU - Nakajima, Kazuaki
AU - Nishiyama, Takahiko
AU - Katsumata, Yoshinori
AU - Aizawa, Yoshiyasu
AU - Fukuda, Keiichi
AU - Takatsuki, Seiji
N1 - Publisher Copyright:
© 2019 Wiley Periodicals, Inc.
PY - 2019/6
Y1 - 2019/6
N2 - Background: Epicardiac conduction via the vein of Marshall (VOM) can bypass the mitral isthmus (MI) line, making MI ablation difficult. This study aimed to assess the contribution of the VOM in achieving MI conduction block. Methods: This study included 143 consecutive patients with nonparoxysmal atrial fibrillation who underwent initial MI ablation. They were retrospectively classified into two groups, a VOM-guided group (n = 28) and a conventional group (n = 115), according to the use of a 2-Fr electrode catheter inserted in the VOM. The acute success rate of achieving MI block and the ablation data were assessed. When the bidirectional block was verified exclusively in the VOM or coronary sinus (CS) electrodes, we defined it as a pseudo MI block. In the VOM-guided group, we ascertained the complete MI block, verified both in the VOM and CS electrodes. Results: In the VOM-guided group, the pseudoblock was observed in 33.3% of the patients during MI ablation. With significantly less radiofrequency energy (19 322.6 ± 11 352.8 vs 25 389.3 ± 19 951.9, P = 0.04), we achieved a similar level of success rate in MI ablation in the VOM-guided group (96.4% vs 91.3%, P = 0.36). Notably, after achieving complete MI block, atrial burst pacing induced two perimitral flutters in the VOM-guided group, which were successfully terminated by the additional radiofrequency application. Conclusions: Assessment of electrical conduction through the VOM could clarify the existence of a pseudo MI conduction block. However, the existence of a slow conduction through the MI could be detected only after induction of perimitral atrial tachycardia with atrial programmed stimulation.
AB - Background: Epicardiac conduction via the vein of Marshall (VOM) can bypass the mitral isthmus (MI) line, making MI ablation difficult. This study aimed to assess the contribution of the VOM in achieving MI conduction block. Methods: This study included 143 consecutive patients with nonparoxysmal atrial fibrillation who underwent initial MI ablation. They were retrospectively classified into two groups, a VOM-guided group (n = 28) and a conventional group (n = 115), according to the use of a 2-Fr electrode catheter inserted in the VOM. The acute success rate of achieving MI block and the ablation data were assessed. When the bidirectional block was verified exclusively in the VOM or coronary sinus (CS) electrodes, we defined it as a pseudo MI block. In the VOM-guided group, we ascertained the complete MI block, verified both in the VOM and CS electrodes. Results: In the VOM-guided group, the pseudoblock was observed in 33.3% of the patients during MI ablation. With significantly less radiofrequency energy (19 322.6 ± 11 352.8 vs 25 389.3 ± 19 951.9, P = 0.04), we achieved a similar level of success rate in MI ablation in the VOM-guided group (96.4% vs 91.3%, P = 0.36). Notably, after achieving complete MI block, atrial burst pacing induced two perimitral flutters in the VOM-guided group, which were successfully terminated by the additional radiofrequency application. Conclusions: Assessment of electrical conduction through the VOM could clarify the existence of a pseudo MI conduction block. However, the existence of a slow conduction through the MI could be detected only after induction of perimitral atrial tachycardia with atrial programmed stimulation.
KW - atrial fibrillation
KW - catheter ablation
KW - mitral isthmus
KW - perimitral flutter
KW - vein of Marshall
UR - http://www.scopus.com/inward/record.url?scp=85063960332&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063960332&partnerID=8YFLogxK
U2 - 10.1111/pace.13640
DO - 10.1111/pace.13640
M3 - Article
C2 - 30779354
AN - SCOPUS:85063960332
SN - 0147-8389
VL - 42
SP - 617
EP - 624
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 6
ER -