抄録
This study was designed to investigate the reliability and validity of measurements of finger diameters with a ring gauge. A reliability study enrolled two independent samples (50 participants and seven examiners in Study I; 26 participants and 26 examiners in Study II). The sizes of each participant's little fingers were measured twice with a ring gauge by each examiner. To investigate the validity of the measurements, five hand therapists compared the finger size and hand volume of 30 participants with the ring gauge and with a figure-of-eight technique (Study III). The intra-class correlation coefficient for intra-observer reliability ranged from 0.97 to 0.99 in Study I, and 0.90 to 0.97 in Study II. The intra-class correlation coefficient for inter-observer reliability was 0.95 in Study I and 0.94 in Study II. The validity study showed a Pearson product moment correlation coefficient of 0.75. The ring gauge showed high reliability and validity for measurement of finger size. Level of evidence: III, diagnostic.
本文言語 | English |
---|---|
ページ(範囲) | 511-515 |
ページ数 | 5 |
ジャーナル | Journal of Hand Surgery: European Volume |
巻 | 42 |
号 | 5 |
DOI | |
出版ステータス | Published - 2017 6月 1 |
外部発表 | はい |
ASJC Scopus subject areas
- 外科