抄録
The authors have previously proposed plastic limit load solutions for thin-walled branch junctions under internal pressure and in-plane bending, based on finite element (FE) limit loads resulting from three-dimensional (3-D) FE limit analyses using elastic-perfectly plastic materials [Kim YJ, Lee KH, Park CY. Limit loads for thin-walled piping branch junctions under internal pressure and in-plane bending. Int J Press Vessels Piping 2006;83:645-53]. The solutions are valid for ratios of the branch-to-run pipe radius and thickness from 0.4 to 1.0, and for the mean radius-to-thickness ratio of the run pipe from 10.0 to 20.0. Moreover, the solutions considered the case of in-plane bending only on the branch pipe. This paper extends the previous solutions in two aspects. Firstly, plastic limit load solutions are given also for in-plane bending on the run pipe. Secondly, the validity of the proposed solutions is extended to ratios of the branch-to-run pipe radius and thickness from 0.0 to 1.0, and the mean radius-to-thickness ratio of the run pipe from 5.0 to 20.0. Comparisons with FE results show good agreement.
| 本文言語 | English |
|---|---|
| ページ(範囲) | 360-367 |
| ページ数 | 8 |
| ジャーナル | International Journal of Pressure Vessels and Piping |
| 巻 | 85 |
| 号 | 6 |
| DOI | |
| 出版ステータス | Published - 2008 6月 |
| 外部発表 | はい |
ASJC Scopus subject areas
- 材料科学一般
- 材料力学
- 機械工学
フィンガープリント
「Limit loads for piping branch junctions under internal pressure and in-plane bending-Extended solutions」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS