Performance evaluation of a novel reticulocyte identification method that uses metachromatic nucleic acid staining based on a crossover analysis of emission DNA/RNA light (RNP Determination™) in hematology analyzer Celltac G+

Kaori Yahagi, Tomoko Arai, Hisako Katagiri, Yoko Yatabe, Hiromitsu Yokota, Yutaka Nagai, Takayuki Mitsuhashi, Masatoshi Wakui, Mitsuru Murata

研究成果: Article査読

抄録

Introduction: Assessing the percentage of reticulocytes (%Retic) is useful for diagnosing and treating blood diseases that present with anaemia. The Celltac G+™ hematology analyzer (HA) uses a novel reticulocyte identification method that involves metachromatic nucleic acid staining with acridine orange and crossover analysis of emission light of DNA/RNA (determination of red cells, nucleic acid-containing cells, and platelets, RNP Determination™). The red and green fluorescence generated by stained single-stranded RNA and double-stranded DNA express immaturity and morphological abnormality of erythrocytes by detecting erythrocyte RNA and DNA content. Methods: The basic performance of the test automated analyzer (TAA) Celltac G+ was evaluated and compared with the flow cytometry reference method and the comparative automated analyzer (CAA) XN-1000/2000™. In addition, its precision, limit of quantity (LoQ), linearity, analytical measurement interval (AMI), accuracy, and comparability and the effects of interfering substances were evaluated. Results: Evaluation of %Retic by the TAA demonstrated good precision and linearity. The AMI was confirmed from 0.02 to 8.23, and the LoQ in %Retic as the coefficient of variation within an 11% limit (SD, within a 0.01 limit) was 0.14. TAA correlated well with the reference method and routine HA (CAA). Some deviations were found between TAA and CAA in DNA measurements of erythrocytes from abnormal samples. Conclusion: Celltac G+ uses a novel measurement principle and can assess erythrocyte immaturity independent of DNA contents. It represents a new HA that provides novel, useful information on immaturity and morphological abnormality of erythrocytes.

本文言語English
ページ(範囲)1050-1059
ページ数10
ジャーナルInternational Journal of Laboratory Hematology
44
6
DOI
出版ステータスPublished - 2022 12月

ASJC Scopus subject areas

  • 血液学
  • 臨床生化学
  • 生化学、医学

フィンガープリント

「Performance evaluation of a novel reticulocyte identification method that uses metachromatic nucleic acid staining based on a crossover analysis of emission DNA/RNA light (RNP Determination™) in hematology analyzer Celltac G+」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル