メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Pipe wall thickness inspection with current driven thermal method

  • Satoshi Honda

研究成果: Conference contribution

抄録

Electric potential difference(EPD) method is widely used for diagnosing and monitoring flow conduits. Theoretical analysis and the exact solution of the electrical potential field in pipe wall have been proposed, and 2D approximation is effective for small pipe wall thickness. This study proposes to use temperature distribution driven by Joule heat with the electric current other than electrical potential difference. Under thin wall approximation, 2D electric and thermal problems are analysed and exact solutions are given.

本文言語English
ホスト出版物のタイトルProceedings of SICE Annual Conference 2010, SICE 2010 - Final Program and Papers
出版社Society of Instrument and Control Engineers (SICE)
ページ1060-1064
ページ数5
ISBN(印刷版)9784907764364
出版ステータスPublished - 2010 1月 1

出版物シリーズ

名前Proceedings of the SICE Annual Conference

ASJC Scopus subject areas

  • 制御およびシステム工学
  • コンピュータ サイエンスの応用
  • 電子工学および電気工学

フィンガープリント

「Pipe wall thickness inspection with current driven thermal method」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。