TY - JOUR
T1 - Pressure-controlled ultrasound probe for reliable imaging in breast cancer diagnosis
AU - Matsumoto, Yukina
AU - Katsumura, Ayu
AU - Miki, Norihisa
N1 - Funding Information:
The authors wish to thank Mrs. Nemoto and Dr. Hayashida of Keio University Hospital for their advice on the design and applications of the device. This research was supported by AMED under Grant Number JP20lm0203012 and by JST SCORE University Promotion Type (Developing the Environment for Creation of Startup Ecosystem in Startup Cities Type), Grant Number JPMJST2074.
Publisher Copyright:
© 2022 The Author(s). Published on behalf of The Japan Society of Applied Physics by IOP Publishing Ltd.
PY - 2022/6
Y1 - 2022/6
N2 - Breast cancer is the most common cancer among women worldwide, with over 2 million new cases diagnosed each year. Early detection can be achieved by screening examinations such as mammography and ultrasonography. The latter has demonstrated advantages such as safety and sensitivity to dense breasts, but is often performed as a follow-up test after abnormal findings at mammography or on palpation. Indeed, the technique shows limitations of operator-dependence and non-reproducibility, since the quality of imaging is highly dependent on the skill of the technologist performing the examination. We therefore designed a diagnosis-assisting device comprising piezoresistive sensors of microscale thickness that can be attached to the ultrasound transducer. The operator is informed when excessive pressure is detected, allowing correction of the transducer position. Finally, we fabricated a breast phantom including tumors from agar and collagen to assess the effectiveness of the device.
AB - Breast cancer is the most common cancer among women worldwide, with over 2 million new cases diagnosed each year. Early detection can be achieved by screening examinations such as mammography and ultrasonography. The latter has demonstrated advantages such as safety and sensitivity to dense breasts, but is often performed as a follow-up test after abnormal findings at mammography or on palpation. Indeed, the technique shows limitations of operator-dependence and non-reproducibility, since the quality of imaging is highly dependent on the skill of the technologist performing the examination. We therefore designed a diagnosis-assisting device comprising piezoresistive sensors of microscale thickness that can be attached to the ultrasound transducer. The operator is informed when excessive pressure is detected, allowing correction of the transducer position. Finally, we fabricated a breast phantom including tumors from agar and collagen to assess the effectiveness of the device.
KW - assisting device
KW - breast cancer diagnosis
KW - breast phantom
KW - pressure sensor
KW - ultrasound transducer
UR - http://www.scopus.com/inward/record.url?scp=85131057386&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85131057386&partnerID=8YFLogxK
U2 - 10.35848/1347-4065/ac58f1
DO - 10.35848/1347-4065/ac58f1
M3 - Article
AN - SCOPUS:85131057386
SN - 0021-4922
VL - 61
JO - Japanese journal of applied physics
JF - Japanese journal of applied physics
IS - SD
M1 - SD1035